Using the ESSS Information Display Utility (EYU9XENF)
The Environment Services System Services (ESSS) information display utility is a TSO/E command processor that can be used to display information about a CICSPlex® SM ESSS.
It is typically used to ensure that no CICSPlex SM address spaces (for example,
CMASes, MASes, and CICSPlex SM
API programs) are connected to the ESSS. Before EYU9XENF can be used,
it needs to be defined as a TSO/E authorized command, and available
to the TSO user as follows:
- Add EYU9XENF to the 'AUTHCMD NAMES' section of the IKJTSOxx SYS1.PARMLIB member used by the MVS™ image.
- Issue from TSO a 'PARMLIB UPDATE(xx)' command to implement the changes made to the IKJTSOxx member.
- Ensure that the SEYUAUTH library that is specified in the TSO user STEPLIB concatenation matches the version of CICSPlex SM that is specified in the EYU9XENF command.
The format of the EYU9XENF command is :
EYU9XENF nnn
where:
- nnn
- Identifies the version of CICSPlex SM for which the ESSS information is to be displayed. This version must match the version of CICSPlex SM specified in the STEPLIB concatenation.
Note: The CMAS information will only be removed after
the CMAS has shutdown and all associated MASes and CICSPlex SM API programs have stopped.