Handling errors for global online change commands

When a global online change command results in an error, the action you perform depends on the state of the IMS™ systems in the IMSplex after the online change error has occurred.

The following table describes actions that you can perform when an online change command results in an error.

Table 1. Handling errors for online change commands
IMSplex state after online change command error User action to perform
One or more IMS systems in prepare complete state after a prepare failure. Issue the TERMINATE OLC command. Correct the problem before reissuing the command.
All IMS systems in prepare complete state. Issue the INIT OLC PHASE(COMMIT) or TERMINATE OLC command.
A mix of IMS systems in prepare complete and commit phase 1 complete state. Correct the problem and try the commit again or issue the TERMINATE OLC command.
All IMS systems in commit phase 1 complete state before OLCSTAT data set updated. Correct the problem and try the commit again or issue the TERMINATE OLC command.
All IMS systems in commit phase 1 complete state after OLCSTAT data set updated. Correct the problem and try the commit again. The online change is committed and cannot be aborted.
Mix of IMS systems in commit phase 1 and commit phase 2 complete state. Correct the problem and try the commit again.
All IMS systems in commit phase 2 complete state. Correct the problem and try the commit again.
Mix of IMS systems in commit phase 2 complete state and not in online change state. Correct the problem and try the commit again.