Information written to tables for a deadlock event monitor
Information written by a deadlock event monitor when the WRITE TO TABLE option is specified.
The sections that follows illustrates the output of a deadlock
event monitor when the WRITE TO TABLE option is used on the CREATE
EVENT MONITOR statement. For information
about the output returned when the event monitor writes to a file
or named pipe, see Event monitor self-describing data stream.
Default table name | Logical data groups reported |
---|---|
CONNHEADER_evmon-name | event_connheader logical data group |
DEADLOCK_evmon-name | event_deadlock logical data group |
DLCONN_evmon-name | event_dlconn logical data group |
CONTROL_evmon-name | The CONTROL logical group consists of selected elements from one or more of the event_dbheader, event_start and event_overflow logical data groups. |
Tables produced
Column Name | Data Type | Description |
---|---|---|
DEADLOCK_ID | BIGINT | deadlock_id - Deadlock Event Identifier monitor element |
DL_CONNS | BIGINT | dl_conns - Connections involved in deadlock monitor element |
EVMON_ACTIVATES | BIGINT | evmon_activates - Number of Event Monitor Activations monitor element |
ROLLED_BACK_AGENT_ID | BIGINT | rolled_back_agent_id - Rolled Back Agent monitor element |
ROLLED_BACK_APPL_ID | VARCHAR(64) | rolled_back_appl_id - Rolled Back Application monitor element |
ROLLED_BACK_PARTICIPANT_NO | SMALLINT | rolled_back_participant_no - Rolled back application participant monitor element |
ROLLED_BACK_SEQUENCE_NO | CHARACTER(5) | rolled_back_sequence_no - Rolled Back Sequence Number monitor element |
START_TIME | TIMESTAMP | start_time - Event Start Time monitor element |