DSNT103I   THE CURRENTLY LOADED DSN6SPRM IS NOT THE MVS/XA VERSION

Explanation

A -START DB2 PARM=xxxxxxxx was issued where 'xxxxxxxx' is the version of the system parameter CSECTs. DB2® executes in a MVS/XA environment and will not execute in any other environment.

System action

The message DSNV086E is generated with a reason code of X'00E30008'. DB2 is terminated with abend code X'04F'.

Operator response

Notify the system programmer.

System programmer response

Restart DB2 with a -START DB2 PARM= command, where the parameter block that follows the 'PARM=' parameter specifies an MVS/XA version of the DB2 subsystem parameters.

Problem determination

Collect the following diagnostic items:
  • Console output from the system on which the job was run, and a listing of the SYSLOG data set for the period of time that spans the failure.
  • Dynamic dump, taken to SYS1.DUMPxx data set, by DB2 (04E and 04F abends).
  • SVC dump (or system dump), taken to SYS1.DUMPxx data set, as result of an operator-initiated dump command or SLIP trap exit.
  • Listing of SYS1.LOGREC data set, obtained by executing IFCEREP1.
  • Listing of DSNZPARM module used.
.