DSNB757I MVS CFRM POLICY STATUS FOR structure-name = status2 MAX SIZE INDICATED IN POLICY = psize KB DUPLEX INDICATOR IN POLICY = dupstat CURRENT DUPLEXING MODE = dupmode ALLOCATED = status1
Explanation
This message is a section of output from the DISPLAY GROUP BUFFERPOOL command, which is part of message DSNB750I.
DSNB757I: CFRM policy status
If DB2®retrieved z/OS® CFRM policy information for the group buffer pool, the DISPLAY GROUPBUFFERPOOL command output includes information about the structure that is associated with the group buffer pool.
DSNB757I - MVS CFRM POLICY STATUS FOR structure-name = status2
MAX SIZE INDICATED IN POLICY = psize KB
DUPLEX INDICATOR IN POLICY = dupstat
CURRENT DUPLEXING MODE = dupmode
ALLOCATED = status1
- structure-name
- The coupling facility structure name for this group buffer pool, such as DSNCAT_GBP0.
- status2
- The z/OS global status of the coupling facility structure. Possible values are:
- NORMAL
- The structure is defined in the current CFRM policy and has no current z/OS restrictions.
- CHNGP
- A change is pending in the structure policy.
- psize
- The size (in KBs) of the coupling facility structure, as indicated in the CFRM policy definition.
- dupstat
- The duplexing attribute for the coupling facility structure, as indicated by the DUPLEX parameter in the CFRM policy definition. Possible values are DISABLED, ENABLED, or ALLOWED.
- dupmode
- The current duplex mode of the group buffer pool. Possible values are:
- SIMPLEX
- The group buffer pool is in simplex mode.
- DUPLEX
- The group buffer pool is in duplex mode.
- INTRAN
- The group buffer pool is in a transition state, either from simplex mode to duplex mode, or from duplex mode to simplex mode. The rebuild status indicator in message DSNB758I gives information about the transition state.
- status1
- An indication of whether the backing coupling facility structure is
allocated:
- YES
- The coupling facility structure is allocated in a coupling facility.
- NO
- The coupling facility structure is not allocated in any coupling facility.