UBA collectors

The UBA collector is associated with two DataChannel components:
Complex Metric Engine (CME)x.x
Performs calculations on the collected data.
File Transfer Engine (FTE)x.x
Transfers files from the collector output directories and places them in the input directory of the CME.
Note: Topology Editor includes the channel and collector numbers in the component names. For example, Data Channel 1 might have Collector UBA 1.1, with Complex Metric Engine 1.1 and File Transfer Engine 1.1.
The FTE writes data to the file /var/adm/wtmpx on each system that hosts a collector. As part of routine maintenance, check the size of this file to prevent it from growing too large. For more information about Disk Quota Management, see Installing Tivoli Netcool Performance Manager - Wireline Component.
Note: The Solaris version can be configured with strict access default settings for secure environments. Strict FTP access settings might interfere with automatic transfers between a DataChannel subchannel and the DataLoad server. Check for FTP lockouts in /etc/ftpd/ftpusers, and check for strict FTP rules in /etc/ftpd/ftpaccess.