On Tivoli Netcool Performance Manager - Wireless component,
you can extract the summary definitions associated with a particular
technology pack from the Tivoli Netcool Performance Manager database.
You can then create a Tivoli Netcool Performance Manager common pack data model containing
a model that report authors can use to create reports by using those
summary definitions.
Before you begin
Ensure that you have configured the JDBC driver in WirelessModelling
tool preferences so that you can connect to the database to extract
the summary definitions.
Procedure
- In WirelessModelling tool, select .
- Enter the project name. Typically, you use the name of
the technology pack.
- Click Next.
- In the Project Explorer, right-click the new project and
select Import. The Import wizard
opens.
- On the Select page of the Import wizard,
expand TNPM Pack Modeling and select Import
Summaries.
- Click Next.
- On the Database details page, specify
the following connection details:
- Host: Hostname where the database is
installed. For example, server.ibm.com
- Username: Username of the system. By
default, For example, virtuo
- Password: Database password
- Database SID: SID name to connect. By default,
vtdb.
- Click Get Summaries. The
database connection is tested.
- Click Next.
- On the Select Installed Packs page,
select one or more technology packs from a list of the installed technology
packs on the system. Select UDC from
the Select Installed Packs page if you want to
create a Tivoli Netcool Performance Manager common pack data model with
user-defined summaries. Make sure that the provisioned summary definition
file has summary type as user. For more information
about the complex summary definition and the associated entities in
the XML file, see Complex summary definition in the Administering Tivoli Netcool Performance
Manager - Wireless Component.
Or, select the technology pack if you want to use the custom summaries.
- Click Next. The Select
Summaries page opens, showing all of the summaries that
are associated with the selected technology packs.
- Select the required summaries by vendor, entity, or summary
name.
- Select the appropriate check box to filter the selected
summaries by raw, hourly, daily, weekly, or monthly intervals. Select
the All summaries check box if you want all.
- Click Next.
- On the Model Details page, specify
the following information:
Option |
Description |
Name |
The model name. Important: You must not use special
characters in the model name.
|
Version |
The model version. |
Vendor |
The vendor name. |
Technology |
The model technology. Important: You must specify
the correct technology for the model to be generated correctly.
|
- On the Save As page, verify the name
for the Common Intermediate Format (CIF) file (.tnpmmodel), select
your project folder, and then click Finish.
- In the Project Explorer, select the CIF file to see the
contents.
- Expand the Summary Definition Set to see the summary definitions
in the model.
- Select to
see the constituent metrics.
- If you are satisfied with the CIF file contents, update
the model properties file as described in Creating a model properties file.
- Generate a Tivoli Netcool Performance Manager common pack data model as
described in Generating the Tivoli Netcool Performance Manager common pack data model contents.
- Publish the Tivoli Netcool Performance Manager common pack data model by
using Framework Manager. For more information, see Publishing a Tivoli Netcool Performance Manager common pack data model.