This tab enables you to define how much information is
recorded while your stub is being executed.
Any information recorded will be logged in IBM® Rational® Integration Tester’s
project results database and on the Test Factory perspective’s
Console window.
The following table describes the list options on
the Logging tab.
List Option |
Description |
None |
No information is logged. |
Normal |
Standard information is logged. |
Debug |
Verbose information is logged. |
Note: If you observe any delays with the stub response
time, set the log level to None. This would avoid any delays due to
the time taken to log details to the results database.
Note: The default list option displayed on the Logging tab
is determined by the setting of the Stub default log level list
on the Console page of the Preferences dialog
box, which is opened by clicking or on the menu bar. Therefore, selecting (for the currently
selected stub) a different log level on the Logging tab
will overwrite the default log level specified in the Preferences
dialog box but only for that stub.