DFR3107E END OF PRIMARY EXTENT DURING OLDS WRITE OPERATION

Explanation

An attempt was made to add log blocks remaining in WADS at the end of OLDS to close the OLDS that was in use when IMS failed, but log blocks or an accounting log record (X'06') could not be written because the OLDS primary extent was already full.

System action

The job ends with an abend code of U3107.

User response

Execute the Log Recovery utility in DUP mode to reserve sufficient space for writing WADS log blocks and the log record X'06'. Then rerun the job.