DFR3100E error_type ERROR IN WADS PROCESSING
Explanation
An attempt to use WADS to close the OLDS that was in use when IMS failed has resulted in error indicated by the error type of error_type.
- Type
- Meaning
- OPEN
- OPEN error.
- READ
- WADS read error.
- SEQUENCE #
- The WADS was read, but there were no required log blocks to close the OLDS.
- CLOSE
- WADS close error.
- VERIFY
- An error occurred while verifying the format of WADS.
- TRKCALC
- MVS™ TRKCALC macro has returned an error code.
- MISSING RCD
- A sequence of WADS records has fewer records than it should.
System action
If the error occurred on a dual WADS, the job continues by using the alternate data set. If errors occurred in both WADSs, or the mode is a single WADS, the job ends with an abend code of U3100.
User response
If the job ended abnormally, make sure that the DD statement for WADS is specified correctly. If there is any error, correct it and rerun the job. If there is no error in the DD statement, contact IBM® Software Support.