DFR1067W OLCSTAT DATA SET DYNAMIC ALLOCATION ENCOUNTERED AN ERROR; RETRYING THE ALLOCATION

Explanation

IMS DEDB Fast Recovery is in a wait state during dynamic allocation of the OLCSTAT data set. This wait occurs because the OLCSTAT data set is being held by another user. IMS DEDB Fast Recovery will reattempt to dynamically allocate the data set and will continue attempting to do so until one of the following conditions are met:
  • The OLCSTAT data set is no longer in use by the other user
  • The maximum number of retry attempts has been reached

System action

If the OLCSTAT data set is freed by the user who is holding it, IMS DEDB Fast Recovery continues processing. If the maximum number of retry attempts has been reached, the job ends with an abend code U1051, accompanied by message DFR1051E.

User response

If the job ends with an abend code U1051, follow the instructions in the User response section of message DFR1051E.