IBM Tivoli Composite Application Manager for Applications, Version 7.2.1.1

Guidelines for monitoring with the CandleMonitor node

See the following guidelines for monitoring with the CandleMonitor node:

  • For production flow statistics, place the CandleMonitor node immediately after MQInput (or other input) nodes and set the type attribute to input.
  • For output rates and counts, place the CandleMonitor node immediately in front of MQOutput, MQReply, and Publication nodes and set the type attribute to output.
  • For any other placement in the flow, do not set the type attribute to input or output, because inaccurate data might be generated.
  • Generally, an eventMessage attribute must be specified only for nodes with a type attribute of subFlowInput, subFlowOutput, and other. Do not set this attribute for the typical processing part of a flow or for a node with a type attribute of input or output (unless the node is not used frequently and there is a specific reason for doing so) because it might have an adverse effect on system performance.

  • For message flow development, nodes that have the type of other can be used to determine areas of a flow that have poor performance.
  • If you are going to shut down the broker or agent, the broker or agent must complete the entire shutdown process whenever possible.