Requirements for servicing a system in EIA locations 30U through 58U

Learn about the requirements for servicing a system that is in Electronic Industries Alliance (EIA) locations 30U through 58U in a rack.

You can use the following table to determine the service requirements for the location of your system within a rack.

Table 1. System EIA location service requirements
EIA location of a system Requirements for a system that remains in the operating position within the rack to service Requirements for a system that must be placed in the service position within the rack to service Requirements for a system that must be removed from the rack to service
1U - 29U No additional service tools are required No additional service tools are required No additional service tools are required
30U - 58U
  • 1 person
  • 1 hard hat
  • 1 5-step platform ladder
  • 1 person
  • 1 hard hat
  • 1 5-step platform ladder
  • 1 ServerLift SL-350X lift tool*
  • 2 people
  • 2 hard hats
  • 2 5-step platform ladders
  • 1 ServerLift SL-350X lift tool
* If you are servicing a system that is in the service position, place the service tools in the following position to increase accessibility:
  • Place the lift tool near the side of the system farthest away from the part that you are replacing.
  • Place the platform ladder near the side of the system closest to the part that you are replacing.

You can use the following table to determine the feature code and part number for ordering the service tools that are needed for servicing a system that is in EIA locations 30U through 58U in a rack.

Table 2. Service tool feature codes and part numbers
Service tool Feature code Part number
Hard hat Not applicable 5442867
5-step platform ladder 1101 Not applicable
ServerLift SL-350X lift tool EB2Z 74Y4399



Last updated: Tue, May 26, 2020