subscribe iconSubscribe to this information
POWER7 information

IVM chled command

Purpose

Change states for physical and virtual LEDs. This command is operable only in an Integrated Virtualization Manager environment.

Syntax

To change virtual partition LEDs:

chled -r sa -t virtuallpar -o Operation { -p PartitionName | --id PartitionID } [ -m ManagedSystem ]

To change virtual system LEDs:

chled -r sa -t virtualsys -o Operation [ -m ManagedSystem ]

Description

The chled command changes the states of physical and virtual LEDs.

Flags

Flag name Description
-r ResourceType The type of LED resource to change. The only valid value is sa for System Attention (SA) LED.
-t SystemAttentionType The type of System Attention (SA) LEDs to change.
-r sa -t virtuallpar

Change attributes for virtual partition system attention LEDs
Attributes:  lpar_id, lpar_name, state
Filters: None

-r sa -t virtualsys

Change attributes for virtual system attention LEDs
Attributes:  state
Filters: None

-o The operation to perform on the LED. Valid values are:
off
deactivate the LED
on
activate the LED
-m ManagedSystem The name of the managed system. This attribute is optional because there is only one system to manage. The name may either be the user-defined name for the managed system, or be in the form tttt-mmm*ssssssss, where tttt is the machine type, mmm is the model, and ssssssss is the serial number of the managed system.
-p PartitionName The name of the partition for which the virtual partition system attention LED is to be changed.
--id PartitionID The ID of the partition for with the virtual partition system attention LED is to be changed.

Exit Status

This command has a return code of 0 on success.

Security

This command is not accessible by users with the ViewOnly role.

Examples

  1. To deactivate the virtual system attention LED for the system, type:
    chled -r sa -t virtualsys -o off
  2. To activate the virtual partition system attention LED for partition lpar3, type:
    chled -r sa -t virtuallpar -o on -p lpar3
  3. To dectivate the virtual partition system attention LED for the partition with ID 3, type:
    chled -r sa -t virtuallpar -o off --id 3


Send feedback Rate this page