IBM Support

V 5.3.0: Updates to the Parameter Reference manual, IBM Tivoli OMEGAMON XE for DB2 Performance Expert on z/OS and DB2 Performance Monitor on z/OS

Product documentation


Abstract

This document describes updates to the IBM® Tivoli® OMEGAMON® XE for DB2® Performance Expert on z/OS® and Performance Monitor on z/OS Parameter Reference manual, SH12-7055-00, for Version 5.3.0

Content

The most recent update is listed first.



Update 2
Date of change: September 2017
Topics: Multiple
Change description: New PARMGEN parameters have been added, and existing parameters have new
defaults or have been updated.

See the following PDF for documentation changes:
v530_techdoc - ko2pr - Sept2017.pdfv530_techdoc - ko2pr - Sept2017.pdf


Update 1
Date of change: November 2015
Topics: Multiple
Change description: Update relating to the features KD2_OMPE_AUTODETECT and KD2_PFnn_SQLPA_VERSION ()

KD2_OMPE_AUTODETECT

Enable autom. DB2 subsystem detection

Description
This feature is part of the OMEGAMON Collector PESERVER subtask. If activated, all active DB2 subsystems in the LPAR are detected automatically, regardless of whether the DB2 subsystem has been explicitly configured during the configuration process or not. You can activate or deactivate this feature:

Y
Automatic detection is activated. Detection of all active DB2 subsystems starts automatically.
N
Automatic detection is deactivated. Only the DB2 subsystems that are explicitly configured are monitored.

If a DB2 subsystem has been detected automatically but has not been configured so far, monitoring is not possible because required bind and grant jobs have not been submitted. Error messages are written to the job log. To enable monitoring the subsystem must be configured as usually with PARMGEN to create the required jobs. The configuration steps of Complete the Configuration must be executed.

Required or optional
Required

Default value
N

Permissible values
Y, N

Location where the parameter value is stored
In the OMPEMSTR member of the rhilev.midlev.rtename.RKD2PAR library
Output line
AUTODETECT=<value>

In the Configuration Tool (ICAT)
Panel name
OMEGAMON Collector Information
Panel ID
KD261PN
Panel field
Automatic DB2 subsystem monitoring
Default value
Y
Permissible values
Y, N

Batch parameter name
KD2_OMPE_AUTODETECT

PARMGEN name
KD2_OMPE_AUTODETECT

PARMGEN classification
OMPE




KD2_PFnn_SQLPA_VERSION

DB2 version for SQLPA

Description
This is the version of the SQL Performance Analyzer. Valid values are 4.1, 4.2 and 5.1

Required or optional
Optional (Required in case KD2_PF_SQLPA_ENABLE is set to Y)

Default value
4.1

Permissible values
4.1, 4.2, 5.1

Location where the parameter value is stored
In the OMPEssid member of the rhilev.midlev.rtename.RKD2PAR library
Output line
SQLPAVERSION=<value>

In the Configuration Tool (ICAT)
Panel name
SQL Performance Analyzer
Panel ID
KD261PQ
Panel field
Version
Default value
4.1
Permissible values
4.1, 4.2, 5.1

Batch parameter name
KD2_PF_SQLPA_VERSION

PARMGEN name
KD2_PFnn_SQLPA_VERSION

PARMGEN classification
SQLPA



Publication number

SH12-7055

Copyright date

2012, 2017

Original publication date

2015/5/29

Document information

More support for: DB2 Tools for z/OS
IBM Tivoli OMEGAMON XE for DB2 PE / PM / BPA

Software version: 5.3.0

Operating system(s): z/OS

Reference #: 7047159

Modified date: 29 September 2017


Translate this page: