IBM Support

Tivoli Netcool/OMNIbus 8.1.0 Fix Pack 11, 8.1.0-TIV-NCOMNIbus-FP0011

Download


Abstract

This fix pack is a cumulative fix release and addresses APARs and internally found issues since the release of OMNIbus 8.1.0 fix pack 10.

Download Description

The following defect solutions are included in this release:

8.1.0-TIV-NCOMNIbus-FP0011
--------------------------

IV83485
The nco_aen client failed to reconnect to the ObjectServer a
second time. The nco_aen client might also fail to reconnect to
the ObjectServer after the first time it looses connection to the
ObjectServer, if the ObjectServer was only unavailable for a
brief period. These problems are now resolved.

Also, it is now possible to suppress the popups that are related
to the connection loss between the nco_aen client and the
ObjectServer. If you want to suppress the popups that are related
to the connection loss, go to the nco_aen.properties file at each
client and set the network.popup property to 0.


IV89382
When the evaluate clause of a trigger contained a 'group by'
statement, and the trigger action had a syntax error, the
ObjectServer used to crash. Now, the syntax error is correctly
reported and the ObjectServer does not crash.


IV91012
Because IDUC is not done on the aggregate ObjectServer connection
in a dual-server desktop setup, the connection might sit idle
while a desktop operator is not performing an action to use the
connection. Some firewalls reset these idle connections, so that
when the desktop operator later performs an action to use the
connection, they see a pop-up error message for the lost
connection. The fix is to silently ping the aggregate
ObjectServer connection to prevent the connection from becoming
idle.


IV91689
The limit to the number of traps that can be generated by the MIB
Manager SNMP Trap Generator, has been removed. The default limit
is '1'. Users can override the default limit with any positive
number. All the values entered in the Trap dialog are saved and
the last value entered will be presented the next time the dialog
is opened.


IV91706
Probe peer-to-peer (P2P) connections might occasionally
incorrectly time out, if the BeatThreshold property was set to 1
second. The probes now perform sub second sleeps between checking
the P2P connection, so the incorrect timeouts do not now occur.


IV93577
The updated code in this fix-pack automatically disables the
problematic DES based ciphers. Install the fix-pack and
everything works as before. No further user interaction is
necessary.

Installation Instructions

OMNIbus core 8.1 must be installed prior to installing this Fixpack.
Fixpacks are cumulative, the latest Fixpack can be applied to update
OMNIbus core to the latest Fixpack version.

IMPORTANT: Before installing this fix, ensure that all Tivoli Network
Management applications on your computer are shut down.

Installation Manager
--------------------
The latest version of Installation Manager is recommended and can be
downloaded from http://www.ibm.com/support/docview.wss?uid=swg27025142

Check the required version of IBM Installation Manager in the IBM Software
Product Compatibility Reports at:
http://publib.boulder.ibm.com/infocenter/prodguid/v1r0/clarity/index.html

Check the Installation Manager and OMNIbus version installed by running the
command:
imcl listInstalledPackages -features -long
which can be found in the following locations:
Windows: install_dir\IBM\Installation Manager\eclipse\tools
Linux and UNIX: install_dir/IBM/InstallationManager/eclipse/tools

Installation manager can be started in console mode by running the command:
imcl -c
which can be found in the following locations:
Windows: install_dir\IBM\Installation Manager\eclipse\tools
Linux and UNIX: install_dir/IBM/InstallationManager/eclipse/tools

Installation manager can be started in GUI mode by running the application:
IBMIM
which can be found in the following locations:
Windows: install_dir\IBM\Installation Manager\eclipse
Linux and UNIX: install_dir/IBM/InstallationManager/eclipse

At any stage if you encounter difficulties using Installation Manager
you can consult the built in help or the latest Installation Manager
documentation by searching IBM Knowledge Center at
https://www.ibm.com/support/knowledgecenter/SSDV2W/im_family_welcome.html.

Using IBM Passport Advantage(r)
-------------------------------
If your computer has internet access and you have an IBM Passport
Advantage account, you can update packages directly from Passport
Advantage.
1. Start Installation Manager.
2. Under the Preferences option, select Repositories and make
sure the "Search service repositories during installation
and updates" is checked.
3. Select the update option and select the "IBM Tivoli Netcool
OMNIbus" entry from the list of packages to find updates for.

Local Repository
----------------
Extract the Fixpack into a new temporary directory, then specify the
repository in the preferences before you update. Each package must
be extracted into a new directory.
1. Start Installation Manager.
2. Under the Preferences option, select Repositories and add a
new repository. Give the location of the extracted
OMNIbusRepository/composite directory
3. Select the update option and select the "IBM Tivoli Netcool
OMNIbus" entry from the list of packages to find updates for.

Electronic Software Delivery(ESD) Zip File
----------------------------------------------
If you have downloaded the ESD for Fix Pack 11 then:
1. Create a directory to store the files and extract the contents
on the zip file into this.
2. If you have installed Installation Manager using either
Administrator or Nonadministrator mode, run the update_gui
script to launch Installation Manager into the update panel
without the requirement of configuring the update repository.
3. If the script fails, or Installation Manager is installed in
Group mode, or you want to run in console mode, then you must
configure the update repository as in the Local Repository
above, with the new repository being the extracted
OMNIbusRepository/composite directory.
4. Select the "IBM Tivoli Netcool OMNIbus" entry from the list of
packages to find updates for.

On
[{"DNLabel":"8.1.0-TIV-NCOMNIbus-FP0011","DNDate":"17 Mar 2017","DNLang":"English","DNSize":"99999999","DNPlat":{"label":"Linux","code":"PF016"},"DNURL":"http://www-933.ibm.com/support/fixcentral/swg/selectFixes?parent=ibm~Tivoli&product=ibm/Tivoli/Tivoli+Netcool+OMNIbus&release=8.1.0.11&platform=All&function=all","DNURL_FTP":" ","DDURL":null}]
[{"Product":{"code":"SSSHTQ","label":"Tivoli Netcool\/OMNIbus"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"--","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"8.1.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Product Synonym

Tivoli Netcool OMNIbus

Problems (APARS) fixed
IV83485;IV89382;IV91012;IV91689;IV91706;IV93577;IV89106;IV89509;IV90524;IV91125;IV91244;IV55784;IV56455;IV56609;IV59634;IV59959;IV60193;IV61491;IV61642;IV62192;IV62891;IV63168;IV63169;IV63203;IV63212;IV63220;IV63222;IV63225;IV63228;IV63229;IV63230;IV63230;IV63234;IV63236;IV63237;IV63248;IV63249;IV63757;IV63758;IV63759;IV51280;IV62328;IV64024;IV64030;IV64823;IV64841;IV65579;IV68196;IV68690;IV68940;IV69161;IV69293;IV69933;IV69934;IV69143;IV70540;IV71122;IV61840;IV67946;IV68107;IV68942;IV72682;IV73109;IV73123;IV73221;IV73279;IV73670;IV73963;IV74587;IV74679;IV74891;IV75451;IV75452;IV75473;IV75482;IV75484;IV75494;IV75501;IV75502;IV75555;IV75641;IV75687;IV75900;IV76107;IV69160;IV75714;IV77594;IV77881;IV78263;IV78277;IV78667;IV78761;IV79182;IV78816;IV79413;IV79952;IV78818;IV80092;IV80567;IV80895;IV81216;IV81225
;IV70937;IV72912;IV79347;IV82539;IV83155;IV83627;IV84051;IV84144;IV84416;IV84442;IV84621;IV84632;IV75048;IV84967;IV85380;IV86599;IV86613;IV87122;IV87274

Document Information

Modified date:
15 June 2018

UID

swg24043466