Download
Abstract
This fix pack is a cumulative fix release and addresses APARs and internally found issues since the release of OMNIbus 7.3.0 fix pack 14.
Download Description
The following defect solutions are included in this release:
IV67129
A probe or gateway cannot connect to an ObjectServer and there is
an error message in the log similar to the following:
ERROR=Argument out of range on line 0 of statement 'select
mod(to_int(log_2(-429171286.0)),131215201) as CS_STRING_TYPE from
catalog.memstores where StoreName='master_store';'
This problem has been resolved.
IV71122
The JRE for Tivoli Netcool/OMNIbus V7.3.0 was updated
to IBM JRE 5.0 SR16 FP9+IV70684 to address possible security
issues.
IV70540
The GSKit component used by Tivoli Netcool/OMNIbus is upgraded to
version 7.0.5.5. This is done to address a potential security
problem that is fixed in this version of GSKit.
IV69143
The LDAP libraries used by Tivoli Netcool/OMNIbus were updated to
TDS version 6.2.0.42 to address potential security issues.
Prerequisites
This fix pack installs on any GA Release (including previous GA fixpacks) of Tivoli Netcool/OMNIbus 7.3.0.
Installation Instructions
UNIX
----
IMPORTANT: Before installing this fix, ensure that all Tivoli Network
Management applications on your computer have been shutdown.
Extract the contents of 7.3.0.15-TIV-NCOMNIbus-<arch>-FP0015.tar
in to a temporary directory, replacing the <arch> placeholder with the
string identifying your platform.
From within the directory enter the following command to install this fix
interactively.
./install.bin
Windows
-------
IMPORTANT: Before installing this fix, ensure that all Tivoli Network
Management applications on your computer have been shutdown.
Extract the contents of 7.3.0.15-TIV-NCOMNIbus-win32-FP0015.zip
in to a temporary directory.
To install this fix interactively double click install.exe.
Problems (APARS) fixed
Was this topic helpful?
Document Information
Modified date:
15 June 2018
UID