IBM Support

Tivoli Netcool/OMNIbus 7.3.0 Fix Pack 13, 7.3.0-TIV-NCOMNIbus-FP0013

Download


Abstract

This fix pack is a cumulative fix release and addresses APARs and internally found issues since the release of OMNIbus 7.3.0 fix pack 12.

Download Description

The following defect solutions are included in this release:

IV51638
A relative include statement in the probe rules file causes the
probe parser to look for a file that is relative to the directory
that the rules file is in. On Windows operating systems, an
incorrect relative path can be generated which causes the include
file to fail to load.
For example, assume that the following include is added to a
simnet.rules file in '/rules/directory/simnet.rules':
include "subdir/probewatch.include"
The probe could fail to start and the following error would be
written to the probe log file:
2013-09-23T16:37:10: Error: E-UNK-000-000: Failed to open Rules
file: /rules/directory/simnet.rules\subdir/probewatch.include
This occurs on Windows operating systems only.


IV50266
The ServerName field is incorrect for GatewayWatch events. This
problem has been resolved.
For new installations, run nco_dbinit as normal.
To apply the fix to an existing installation, you must manually
update the new_row trigger in automation.sql. To do this, take
one of the following actions:
1) Copy the new_row trigger from the default automation.sql file.
2) Alternatively, edit the new_row trigger in automation.sql and
change this line:
if ( %user.is_gateway = false )
to this:
if ( ( %user.is_gateway = false ) OR (( new.Manager =
'GatewayWatch' ) AND ( new.ServerSerial = 0 )) )


IV51848
The GSKit component used by Tivoli Netcool/OMNIbus is upgraded to
version 7.0.4.48. This is done to address a potential security
problem that is fixed in this version of GSKit.


IV53291
In a pre-insert table trigger, if another insert is performed
into the same table then an inconsistency is created during the
the nested table trigger. Any column of type incr will have the
incorrect value available via the new.column-name variable in the
nested trigger. The column value in the resulting row will be
correct.
An example of this is when a trigger inserts a new row into the
alerts.status table and the default new_row trigger assigns
Serial (an incr field) to ServerSerial. When the rows are
committed, the Serial fields are set so that each row has a
unique value but the ServerSerial field retains the original
value. This causes the two rows to have the same ServerSerial
value but different Serial values.
This problem is resolved.


IV54051
Rules files that contain 'IF' blocks with a large number of 'ELSE
IF' clauses can cause a stack overflow in the rules file parser
when a probe starts up. This problem is fixed.


IV55408
The JRE for Tivoli Netcool/OMNIbus V7.2.1 and V7.3.0 was updated
to IBM JRE 5.0 SR16 FP5 to address possible security issues.


IV56421
The following message is issued when running nco_store_resize on
AIX:
Fatal: F-UNK-003-007: Environment variable XPG_SUS_ENV must be
set to "ON"
This problem has been resolved.

Prerequisites

This fix pack installs on any GA Release (including previous GA fixpacks) of Tivoli Netcool/OMNIbus 7.3.0.

Installation Instructions

UNIX
----

IMPORTANT: Before installing this fix, ensure that all Tivoli Network
Management applications on your computer have been shutdown.

Extract the contents of 7.3.0.13-TIV-NCOMNIbus-<arch>-FP0013.tar
in to a temporary directory, replacing the <arch> placeholder with the
string identifying your platform.

From within the directory enter the following command to install this fix
interactively.

./install.bin

Windows
-------

IMPORTANT: Before installing this fix, ensure that all Tivoli Network
Management applications on your computer have been shutdown.

Extract the contents of 7.3.0.13-TIV-NCOMNIbus-win32-FP0013.zip
in to a temporary directory.

To install this fix interactively double click install.exe.

On
[{"DNLabel":"7.3.0-TIV-NCOMNIbus-FP0013","DNDate":"11 Apr 2014","DNLang":"English","DNSize":"999999999","DNPlat":{"label":"Linux","code":"PF016"},"DNURL":"http://www-933.ibm.com/support/fixcentral/swg/quickorder?parent=ibm%7ETivoli&product=ibm/Tivoli/Tivoli+Netcool+OMNIbus&release=7.3.0.13&platform=All&function=all&source=fc","DNURL_FTP":" ","DDURL":null}]
[{"Product":{"code":"SSSHTQ","label":"Tivoli Netcool\/OMNIbus"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"--","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"7.3.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Problems (APARS) fixed
IV51638;IV50266 ;IV51848 ;IV53291;IV54051;IV55408;IV56421;IZ37272;IZ60407;IZ62951;IZ62720;IZ67228;IZ63491;IZ55799;IZ65930;IZ65261;IZ65536;IZ65290;IZ35655;IZ74616;IZ60269;IZ62580;IZ63926;IZ66216;IZ66645;IZ66738;IZ68706;IZ70481;IZ70653;IZ66383;IZ69057;IZ71966;IZ70104;IZ67525;IZ69099;IZ65925;IZ68862;IZ72292;IZ75578;IZ75853;IZ75955;IZ70187;IZ76225;IZ76040;IZ77352;IZ78305;IZ79684;IZ80143;IZ77515;IZ81037;IZ82721;IZ80783;IZ80678;IZ75736;IZ84694;IZ84890;IZ78509;IZ85473;IZ86656;IZ84650;IZ86876;IZ83743;IZ81420;IZ84304;IZ86660;IZ89203;IZ69192;IZ88264;IZ89336;IZ89804;IZ89246;IZ93135;IZ83167;IZ89652;IZ90120;IZ90590;IZ90595;IZ90998;IZ91033;IZ91353;IZ91625;IZ92035;IZ92158;IZ87156;IZ88638;IZ93232;IZ94582;IZ91372;IZ94560;IZ94812;IZ95387;IZ95056;IZ95606;IZ92421;IZ95999;IZ95859;IZ96030;IZ90073;IZ92957;IZ98709;IV00626;IZ99164;IZ96997;IZ99399;IV00053;IV00327;IZ99173;IV00798;IV00913;IV00055;IZ97176;IZ99240;IZ95632;IV01471;IV00664;IV02355;IV01879;IV02710;IV02854;IV03306;IV03376;IV03548;IV05509;IV09805;IV07754;IV06469;IV06741;IV07762;IV07752;IV07175;IV08432;IV09109;IV02376;IV08759;IV09178;IV09804;IV08541;IV10583;IV02275;IV03986;IV08717;IV11903;IV12215;IV12301;IV12632;IV12806;IV12946;IV13130;IV14461;IV14474;IV14576;IV16502;IV16605;IV20835;IV21469;IV23496;IV24763;IV24608;IV22826;IV15415;IV23925;IV27193;IV28712;IV28264;IV32015;IV32957;IV34002;IV25000;IV29952;IV38671;IV39542;IV37676;IV41237;IV44077;IV44138;IV44511

Document Information

Modified date:
15 June 2018

UID

swg24036691