IBM Support

Using IBM DB2 Analytics Accelerator Loader for z/OS (5639-OLE) may result in errors

Technote (troubleshooting)


Problem(Abstract)

Using IBM DB2 Analytics Accelerator Loader for z/OS (5639-OLE) may result in errors after upgrading IBM DB2 Analytics Accelerator for z/OS Version 5.1.0 to maintenance level PTF-4.

Environment

Users affected
Users of IBM DB2 Analytics Accelerator for z/OS

  • Version 5.1.0, maintenance level PTF-4
running IBM DB2 Analytics Accelerator Loader for z/OS may experience the following error messages:

HLOU5700E 073 06:03:33.67 Error from call to HLOPIPE from HLOUTMGR Function=02 RC=05
HLOU5365E 073 06:03:33.67 Error parms: 00000081, 05620062, 61A39497, 618198A3.
HLOU4031E 073 06:03:33.67 HLPPIPE OPEN did not return any valid file descriptors for table partition: 0
HLOU5022E 073 06:03:33.67 Subtask HLO$TMGR terminated unexpectedly. SYS=0000, USR=0008


Resolving the problem

Apply PTF UI46561 for APAR PI78727 to get the error in IBM DB2 Analytics Accelerator Loader for z/OS fixed.

Document information

More support for: DB2 Analytics Accelerator for z/OS

Software version: 5.1.0

Operating system(s): z/OS

Reference #: 2002764

Modified date: 11 May 2017


Translate this page: