This list provides information about limitations and known issues that you might encounter when you use IBM® Tivoli® Storage Productivity Center Version 5.2.1 or Tivoli® Storage Productivity Center for Replication Version 5.2.1.

Content

To access all of the support documentation, including alerts and APARs, go to the IBM Support Portal.

For the list of known issues for Tivoli Storage Productivity Center Version 5.2, see http://www.ibm.com/support/docview.wss?uid=swg21622351.

For a list of known issues with the Tivoli Storage Productivity Center support for Hitachi Data Systems Virtual Storage Platform, see http://www.ibm.com/support/docview.wss?uid=swg21667294.

For information about the devices that are supported by Tivoli Storage Productivity Center Version 5.2.1, see the support matrix at https://www.ibm.com/support/docview.wss?uid=swg21386446

To see the IBM Tivoli Storage Productivity Center Version 5.2 Quick Installation Guide, see the Printable Documentation page in the Tivoli Storage Productivity Center knowledge center.

APAR IT11343: Tivoli Storage Productivity Center for System z documentation incorrectly references the portdef.props configuration file

The Tivoli Storage Productivity Center for System z Installation Guide, User's Guide, and Knowledge Center contain references to the "portdef.props" configuration file. These publications should reference the "bootstrap.properties" file in the
path_prefix/opt/Tivoli/RM/wlp/usr/servers/replicationServer/ location. This incorrect reference to portdef.props occurs in two topics in the System z documentation:
Ports
Starting the Tivoli Storage Productivity Center for Replication for System z GUI

You can track the status of this APAR here: https://www-01.ibm.com/support/entdocview.wss?uid=swg1IT11343

The documentation incorrectly states that single sign-on can be configured for DS8000 Storage Manager, SAN Volume Controller, and Storwize V7000

In the product documentation, there are instructions for how to configure single sign-on between Tivoli Storage Productivity Center and DS8000 Storage Manager, SAN Volume Controller, and Storwize V7000. However, the single sign-on function is not enabled for this release. It is recommended that you ignore the documentation related to single sign-on for external applications.

Ignore references to Configuration Utility and Tivoli Integrated Portal in the product documentation

The Tivoli Storage Productivity Center Knowledge Center incorrectly references the Configuration Utility and Tivoli Integrated Portal as components of Tivoli Storage Productivity Center. These components are no longer included with Tivoli Storage Productivity Center and references to these components can be ignored.


Disable Windows User Account Control to edit configuration files

On Windows installations, if you installed Tivoli® Storage Productivity Center by using a domain user account, you must disable User Account Control to edit the configuration files.

Incorrect links in Tivoli Storage Productivity Center reports during an upgrade topic

In the online product documentation for Tivoli Storage Productivity Center, the Tivoli Storage Productivity Center reports during an upgrade topic contains incorrect links to the Tivoli Common Reporting documentation. Use the following links:

http://www.ibm.com/support/knowledgecenter/SSEKCU_1.1.0.3/com.ibm.psc.doc_1.1.0.3/tcr_original/ttcr_upgrading.html

http://www.ibm.com/support/knowledgecenter/SSEKCU_1.1.0.3/com.ibm.psc.doc_1.1.0.3/tcr_original/ttcr_upgrading_external.html

Incorrect link in Troubleshooting Jazz for Service Management installation procedure topic

In the online product documentation for Tivoli Storage Productivity Center, the Troubleshooting Jazz for Service Management installation procedure topic contains an incorrect link to the Jazz for Service Management documentation. Use the following link:

http://www.ibm.com/support/knowledgecenter/SSEKCU_1.1.0.3/com.ibm.psc.doc_1.1.0.3/ref/psc_r_install_smsetappserver_cmd.html

Installing Jazz for Service Management

The following information applies to the installation of Jazz for Service Management:

  • If you install Jazz for Service Management with Tivoli Storage Productivity Center on AIX 7.1TL3 (SP0-1), you must first apply the AIX fixes for
  • To install Jazz for Service Management and Tivoli Common Reporting, the following compressed files must be downloaded and extracted to a single directory (for example, c:\downloads\JazzSM):
    • Jazz for Service Management
    • Tivoli Common Reporting
    • Tivoli Common Reporting
    • IBM WebSphere Application Server
  • Disk space requirements for each server on which you plan to install Jazz for Service Management and Tivoli Common Reporting. If you are using downloaded installation packages from Passport Advantage Online or IBM Fix Central, the downloaded packages must be unpacked to a local disk or file system on each server on which you install these two components.
    • Windows:
      • 5 GB free disk space on the C: drive for temporary installation files and other necessary files that will remain on the server
      • 10 GB additional free disk space on the target installation disk for the Jazz for Service Management and Tivoli Common Reporting program files
      • Additional free disk space for the installation images, including the images that you download and the resulting unpacked files; this might require as much as 10 GB additional free disk space
    • AIX/Linux:
      • 5 GB free disk space on the root file system for temporary installation files and other necessary files that will remain on the serve
      • 10 GB additional free disk space on the target installation disk for the Jazz for Service Management and Tivoli Common Reporting program files]
      • Additional free disk space for the installation images, including the images that you download and the resulting unpacked files; this might require as much as 10 GB additional free disk space

  • When you install Jazz for Service Management, you must use the Tivoli Storage Productivity Center installation program. If you do not use the Tivoli Storage Productivity Center installation program, you will experience the following types of issues:

    • The Jazz for Service Management Windows service is not created.


    • As a result, the Jazz for Service Management server does not automatically start when you restart the computer or log off of your Windows session. Tivoli Storage Productivity Center reports cannot connect to Jazz for Service Management. You must manually start Jazz for Service Management server every time you restart the computer or log off of your Windows session on which Jazz for Service Management is installed.

      To start the Jazz for Service Management server, run the following command:

      JazzSM_install_directory\profile\bin\startServer.bat server_name

      JazzSM_install_directory and server_name were specified when you installed Jazz for Service Management. The default JazzSM_install_directory is C:\Program Files\IBM\JazzSM, and the default server_name is server1.

      It might take a few minutes for the server to start.

      You can also return the name and status of the server by entering the following WebSphere® Application Server command:

      serverStatus -All
    • Jazz for Service Management launchpad uses the same default ports as IBM® Tivoli Integrated Portal Version 1.1, which can create a port conflict when you upgrade to Version 5.2.1.
      When you upgrade from Tivoli Storage Productivity Center Version 4.2 (or later) to Tivoli Storage Productivity Center Version 5.2.1, there is a port conflict, the Jazz for Service Management launchpad does not provide an option to use non-default ports. The Jazz for Service Management launchpad also does not detect the port conflict if the Tivoli Integrated Portal Version 1.1 server is down.
    • If you try to install Jazz for Service Management separately by using a Windows domain user account, the installation will fail.

    • If you try to install Jazz for Service Management by using a version of IBM® Installation Manager that is lower than Version 1.6.1, the Jazz for Service Management installation will fail with error message CRIMA1099E. To complete the Jazz for Service Management installation, you must upgrade Installation Manager to Version 1.6.1 or later. For instructions about upgrading Installation Manager, see http://www.ibm.com/support/knowledgecenter/SSNE44_5.2.1/com.ibm.tpc_V521.doc/fqz0_t_upgrading_im.html.


APAR IT06215: Uninstalling the Deployment Engine

The Knowledge Center and Installation Guide topic Uninstalling Tivoli Common Reporting and Jazz for Service Management does not contain information about how to remove the Deployment Engine, which is a component of Tivoli Common Reporting. For instructions about how to remove the Deployment Engine, see http://www-01.ibm.com/support/knowledgecenter/SSEKCU_1.1.0.3/com.ibm.psc.doc_1.1.0.3/tcr_original/ttcr_uninstal_manually.html.

You can see the status of this APAR here: http://www.ibm.com/support/docview.wss?uid=swg1IT06215

Documentation update: Port numbers must be manually validated when installing Jazz for Service Management without a web browser

The topic Installing Jazz for Service Management and Tivoli Common Reporting on AIX without a web browser is missing information about manually validating port numbers during the installation of Jazz for Service Management. Step 19 in this procedure should be:


19. Review your port configuration and click Next.

Important: You must verify that the ports you specify on this page are
available and not being used by other applications. If any of the specified
ports are in use, change those values to ports you know are available before
installing Jazz for Service Management.

Attention: If you are upgrading from Tivoli Storage Productivity Center
Version 4.2.2 to Version 5.2 (or later), Jazz for Service Management and IBM
Tivoli Integrated Portal can use port 16310. If there is a port conflict, you must
change the value of the HTTP transport port.

This update applies to the topic in the 5.2.1 Knowledge Center and the 5.2.1 Installation Guide.


Tip for scheduling probes

When scheduling probes to collect data about resources, schedule the probes to run at different times. By scheduling data collection so that no two probes run at the same time, you can help improve the overall performance of the product and ensure that data is collected successfully. Probes are scheduled when you add resources for monitoring, and you can modify schedules at a later time. To modify the schedule for an existing probe, complete the following steps:
  1. Access the web-based GUI.
  2. From the navigation pane, go to the resource list page for a resource type. For example, to modify a probe schedule for a storage system, click Storage Resources > Storage Systems.
  3. Right-click the resource that you want to modify and select Data Collection > Schedule.
  4. On the Data Collection Schedule window, modify the schedule for the probe and click Save.

Displaying the web-based GUI in high contrast mode

You might encounter minor issues if you view the web-based GUI in high contrast mode. For example, if you enter invalid data in a field, an error message is displayed but the field is not highlighted.

PDF files do not export correctly in languages and locations with non-Latin 1 code pages

In the Tivoli Storage Productivity Center web-based and stand-alone GUIs, PDF files do not export correctly in languages and locations where non-Latin 1 code pages are used. When you try to export the file, the non-Latin 1 characters are stripped from the output.

The affected languages are:
  • Chinese (Simplified)
  • Chinese (Traditional)
  • Czech
  • Hungarian
  • Japanese
  • Korean
  • Polish
  • Russian

When you export to CSV and HTML, the correct output is generated in all languages and locations.

You must use Tivoli Common Reporting to generate reports and export these reports as PDF files. For more information about exporting reports as PDF files, see IBM Cognos Business Intelligence information center Version 10.1.1. Search for Export Data in PDF Format.
    Installing DB2 using a Windows domain user account requires Schema Administration authority

    If you are installing DB2 using a Windows domain user account, you must first log on to Windows using a domain administrator user account that has Schema Administration authority. Otherwise the DB2 installation task will fail. The requirement for Schema Administration authority was omitted from the Knowledge Center topic describing this installation process: "Installing DB2 by using a Windows domain user account".

    Installing on a Windows domain - documentation corrections

    Topic title: Installing Tivoli Storage Productivity Center on a Windows domain

    This Knowledge Center topic requires changes to step 2 in two sections.

    Section title: Installing DB2 and Tivoli Storage Productivity Center by using local user accounts

    Updated step 2 in this section:
    2. Log on to the Windows domain computer on which you plan to install Tivoli Storage Productivity Center by using a local user account that is a member of the local administrator and the local DB2 administrator (DB2ADMNS) groups.

    Section title: Installing DB2 by using a local user account and Tivoli Storage Productivity Center by using a domain user account

    Updated step 2:
    2. Log on to the Windows domain computer on which you plan to install Tivoli Storage Productivity Center by using a domain user account that is a member of the local administrator and the local DB2 administrator (DB2ADMNS) groups.
    This user must have the 'Act as part of the operating system' and 'Login as a
    service' permissions set in the security policy.

    The installation of Tivoli Common Reporting fails with insufficient space on the disk partition

    The Tivoli Common Reporting installation program fails when the DB2 Content Store database for Tivoli Common Reporting is installed on a different server from the server on which you plan to install Jazz for Service Management and Tivoli Common Reporting. The Tivoli Common Reporting installation program fails when 8 KB of additional DB2 table space is requested from the disk partition because there is not enough space on the disk partition.

    To resolve this issue, ensure that you have sufficient space in the remote disk partition for the DB2 table space before you install Tivoli Common Reporting.

    This issue will be fixed in a future release of Tivoli Common Reporting.
      Incorrect roles-to-group mappings in Tivoli Storage Productivity Center Version 5.1 (or later) result in login issues after you upgrade to Tivoli Storage Productivity Center Version 5.2

      In Tivoli Storage Productivity Center Version 5.1 (or later), if you did not complete a correct roles-to-group mapping, you can experience login issues in the web-based GUI after you upgrade to Version 5.2. These issues occur because there was no roles-to-group mapping validation in previous Tivoli Storage Productivity Center versions.

      Tip: Role-to-group mapping is defined as one group that is mapped to one role and this group is declared at the operating system level.

      To avoid this issue, after you upgrade to Tivoli Storage Productivity Center Version 5.2, log in to the web-based GUI by using one of the following credentials:
      • A valid root ID (on UNIX operating systems)
      • A valid administrator ID (on Windows operating systems)

      The Administrator role in Version 5.2 was the superuser role in Version 5.1.

      To correct the previous role-to-group mapping, after you log in to the web-based GUI, click Setting > User management.

      The provisioning task is deleted if you return to the Provision Storage wizard

      When you complete the steps in the Provision Storage wizard, Tivoli Storage Productivity Center determines the best location for the storage and displays a provisioning task. Depending on your role and permissions, you can save, run, or schedule the provisioning task. However, if you return to the Provision Storage wizard, the provisioning task is deleted. You can resubmit the provisioning request, but Tivoli Storage Productivity Center recalculates the storage placement recommendation. The storage placement recommendation is recalculated even if you do not modify any of the requested storage specifications.

      The source location for DB2 Version 10.1 or later is not required for DB2 Version 9.7

      The Jazz for Service Management installation wizard includes the field The IBM DB2 10.1 or later, Enterprise Server Edition installation image on the Specify Source Locations page of the wizard. If you leave this field blank, the following message is displayed:

      The IBM DB2 10.1 or later, Enterprise Server Edition installation image field is empty.
      This field is required when you want to install DB2.

      If you are using DB2 Version 9.7, disregard this message and leave the field blank.

      For a list of DB2 versions and fix packs that you can use with Tivoli Storage Productivity Center Version 5.2, see the support matrix at https://www.ibm.com/support/docview.wss?uid=swg21386446. Click the 5.2.x link under Agents, Servers and Browsers.

      Cannot report detailed back-end storage information for a DS5000 or a DS4000 system

      If a SAN Volume Controller uses back-end storage from a DS5000 system or a DS4000 system, some information about the back-end storage might be missing. If you did not create explicit host connections for the back-end disks on the DS5000 or DS4000 system, the following problems might occur:
      • The CIM agent for the DS5000 or DS4000 system does not report any detailed information about the back-end storage.
      • Tivoli Storage Productivity Center cannot provide other information about the back-end storage for the consuming disk system. For example, Tivoli Storage Productivity Center cannot provide RAID information.

      Therefore, you must create explicit host connections for the back-end disks on the DS5000 or DS4000 system. It is not sufficient to associate the back-end disks with the default host group.

      Tivoli Storage Productivity Center cannot detect the mount status of file systems on Scale Out Network Attached Storage and Storwize V7000 Unified storage systems

      If a file system is manually unmounted from an IBM® Scale Out Network Attached Storage (SONAS) or Storwize V7000 Unified storage system, Tivoli Storage Productivity Center cannot detect that the file system was unmounted. Because of this limitation, information that is displayed in the Tivoli Storage Productivity Center GUIs is not accurate and some storage-related actions on the file system might fail.

      For example, when you provision storage, a file system on a Storwize V7000 Unified storage system might be recommended for provisioning. However, if that file system was manually unmounted after it was first detected by Tivoli Storage Productivity Center, the provisioning action will fail. An unmounted file system cannot be used for provisioning. To avoid this issue, ensure that the monitored file systems on the Storwize V7000 Unified storage system are mounted before you run the provisioning action.

      Using a virtual private network connection to install Tivoli Storage Productivity Center can cause problems

      Do not use a virtual private network (VPN) connection to install Tivoli Storage Productivity Center. This type of network connection can create problems with the installation.

      If you are using a VPN connection, disconnect it before you install Tivoli Storage Productivity Center. After you install Tivoli Storage Productivity Center, you can reconnect the VPN connection.

      Some resources on SAN Volume Controller and Storwize systems temporarily show an incorrect status

      The status of internal disks on SAN Volume Controller and Storwize systems is only updated after a probe of the storage system. The status of an internal disk on a SAN Volume Controller or Storwize system might be updated between probes from Tivoli Storage Productivity Center. In this case, the status of the disk in the Tivoli Storage Productivity Center web-based GUI might be temporarily out of date. You can check the status of an internal disk in the SAN Volume Controller and Storwize system user interface.

      Jazz for Service Management directories remain after you uninstall Tivoli Common Reporting

      After you uninstall Tivoli Common Reporting, the follow directories might still remain in the C:\Program Files\IBM\JazzSM directory:
      • bin
      • etc
      • lib
      • logs
      • profile
      • reporting
      • var
      A new IBM SONAS file set might be mistakenly deleted

      The file set information was deleted in the other system before the new file set with the existing ID was created."

      If Tivoli Storage Productivity Center discovers a new IBM SONAS file set, the ID of a deleted file set might be reused for the new file set. If you delete the older file set in Tivoli Storage Productivity Center, the new file set is deleted instead. This issue occurs in the following circumstances:
      • A file set that is known to Tivoli Storage Productivity Center is deleted in a system other than Tivoli Storage Productivity Center.
      • Tivoli Storage Productivity Center retained the deleted file set information, either because the probe was not run after the file set was deleted or because the retention period of the file set has not expired.
      The file set information was deleted in the other system before the new file set with the existing ID was created.
        The prerequisite checker checks the /usr directory instead of the /opt directory

        On Linux and AIX operating systems, when you install Jazz for Service Management and Tivoli Common Reporting, instead of checking the /opt directory for free space, the prerequisite checker checks the /usr directory. Ensure that you have sufficient space in the /opt directory.

        Unable to restart Jazz for Service Management services when Jazz for Service Management is installed without using the Tivoli Storage Productivity Center installation program

        On the Windows operating system, if you installed Jazz for Service Management and Tivoli Common Reporting without starting the Tivoli Storage Productivity Center installation program, and you log off or restart your computer, Jazz for Service Management and Tivoli Common Reporting services do not automatically start. You must manually restart the Jazz for Service Management and Tivoli Common Reporting services. For information about restarting Jazz for Service Management and Tivoli Common Reporting services, see Tivoli Storage Productivity Center knowledge center. Search for Starting Tivoli Storage Productivity Center servers.

        To resolve this issue, you must install Jazz for Service Management and Tivoli Common Reporting by using the Tivoli Storage Productivity Center installation program.

        Restriction: If your computer is part of a Windows domain, to avoid the Access Denied message, you must run the startServer command with the runas parameter.

        Discrepancy about the space requirement in the /opt folder to install Jazz for Service Management

        Although you need 6 GB in the /opt folder to install Jazz for Service Management, the Prerequisite Scanner check states that you need only 4.6 GB.

        To resolve this issue, before you install Jazz for Service Management, ensure that you have at least 6 GB of space in the /opt folder.

        The change password tool cannot restart the Device server

        When you run the change password tool, the following message is displayed:
        There was an error restarting the Device server. Restart the server manually.

        To manually start the Device server, follow these steps:

        On Windows operating systems:
        1. At the command prompt, go to the TPC_installation_directory\scripts directory.
        2. Run the stopTPCDevice.bat command.
        3. Run the startTPCDevice.bat command.

        On AIX or Linux operating systems:
        1. At the command line, go to the TPC_installation_directory/scripts directory.
        2. Run the ./stopTPCDevice.sh command.
        3. Run the ./startTPCDevice.sh command.

        Tier and Easy Tier refer to different properties in Tivoli Storage Productivity Center reports

        In Tivoli Storage Productivity Center reports, the Storage Virtualizer Pool Tier property refers to the tier that a pool is assigned to in the web-based GUI. The following properties refer to Easy Tier information for SAN Volume Controller and Storwize V7000 systems:
        • Storage Virtualizer Pool Tier Capacity
        • Storage Virtualizer Pool Tier Available Space
        • Storage Virtualizer Pool Tier Number of MDisks
        • Storage Virtualizer Tier Type
        • Storage Virtualizer Pool Is Easy Tier
        • Storage Virtualizer Pool Easy Tier Status
        The Status column on the Storage Systems page might show a status of Normal when the initial probe fails for a storage system

        After you run a probe on a storage system for the first time, the Status column on the Storage Systems page might incorrectly show a status of Normal when the probe fails. The Status column on the Pools page also might show a status of Normal for pools that are configured in the storage system. The Probe Status column on the Storage Systems page correctly shows a status of Failed.

        Data that was collected by the probe before the error occurred is saved in the database and is incorrectly included in the Available Pool Space value on the Pools page and the Available Space value on the Service Class page.

        To fix this problem, resolve the issue that caused the probe failure and run the probe again for the storage system. You can view the error message in the logs for the probe run.

        The Pool Performance table incorrectly displays the pool status as unreachable after the initial probe

        In some cases, the status of a pool displays in the Pool Performance table as unreachable after the initial probe of the device. The status of the pool displays correctly in the Pools page. To resolve the incorrect status, wait approximately 10 minutes and run the probe again.

        Some characters might not be displayed correctly in reports in PDF format

        Characters from the Mongolian, Tibetan, or Yi languages are displayed as square boxes in reports in PDF format. To resolve this problem, you must enable IBM Cognos to display Chinese characters correctly. For more information about how to enable IBM Cognos to display Chinese characters correctly, see the IBM Cognos Business Intelligence 10.2.0 information center. Search for Chinese characters.

        Running multiple optimization recommendations at the same time results in a Pool Exhaustion Exception error

        In some cases, running more than 15 optimization recommendations at the same time can cause one or more of the individual recommendation executions to result in a Pool Exhaustion Exception error. This can be caused by a lack of available resources in the operating system thread pool. You can manually complete the failed recommendations.

        If this situation occurs frequently, contact IBM Support for assistance in reducing the number of concurrently running optimization recommendations.

        A provisioning request for the DS8000 system fails when insufficient free volume IDs are available

        When you specify a provisioning request to create multiple volumes on a DS8000 system that does not have enough free volume IDs on the even or odd logical subsystems (LSS) to fulfill the request, the remaining volumes are not created.

        To resolve this issue, do not specify more than the available LSS volumes when creating a
        provisioning request to create volumes on a DS8000 system.

        Information is missing in the Adding an LDAP repository to the federated repositories information center topic

        The following information is missing from the end of the Tivoli Storage Productivity Center Version 5.2 information center topic, Adding an LDAP repository to the federated repositories:
          **For Tivoli Storage Productivity Center LDAP configurations, you must add the group from the LDAP server to Tivoli Storage Productivity Center.

          In the Tivoli Storage Productivity Center web-based GUI, click Settings > User management > Add group to log in to Tivoli Storage Productivity Center by using the LDAP user name.

          **For Tivoli Storage Productivity Center for Replication LDAP configurations, you must add the LDAP group in the Tivoli Storage Productivity Center for Replication GUI to log in to Tivoli Storage
          Productivity Center for Replication with the LDAP user name.


        Some hyperlinks in the VMware vSphere web client do not work correctly when using Google Chrome

        When using the Google Chrome Version 29 browser, some hyperlinks from the vSphere web client to the Tivoli Storage Productivity Center web-based UI result in a This web page is not available error. This is caused by the browser not handling certificates properly.

        To resolve this issue, refresh the browser window. This will cause the browser window to display the Certificate not trusted window. Click Proceed anyway to continue to the Tivoli Storage Productivity Center web-based GUI.

        Documentation is available to upgrade a DB2 server on Linux or UNIX operating systems

        Documentation for upgrading a DB2 server on a Windows operating system is included in the Tivoli Storage Productivity Center information center and IBM Tivoli Storage Productivity Center Version 5.2 User's Guide. For documentation about how to upgrade a DB2 server on a Linux or UNIX operating system, see the IBM DB2 Version 10.1 information center. Search for Upgrading a DB2 server (Linux and UNIX).

        Unable to run Tivoli Storage Productivity Center reports when you upgrade from Tivoli Storage Productivity Center Version 5.1.1.2 to Version 5.2.1 on AIX operating systems

        On AIX operating systems, before you upgrade from Tivoli Storage Productivity Center Version 5.1.1.2 to Version 5.2.1, verify whether Tivoli Storage Productivity Center reports work. If reports do not work, some of the files that were bound to DB2 may have been deleted. If this occurs, you cannot run Tivoli Storage Productivity Center reports.

        Restriction: You must complete the following procedure before you upgrade to Tivoli Storage Productivity Center Version 5.21. After you complete the procedure, verify that you can run Tivoli Storage Productivity Center reports, and then upgrade to Tivoli Storage Productivity Center Version 5.2.1.

        To resolve this issue, complete the following steps:
        1. Log in to Tivoli Storage Productivity Center by using the root user name.
        2. At the command line, issue the following commands:
        su - db2inst1
        db2 terminate
        db2 connect to tpcdb
        db2 bind /opt/IBM/db2/V9.7/bnd/db2schema.bnd blocking all grant public sqlerror continue
        db2 terminate

        The Performance tab is displayed for storage system disks for which performance information is not supported

        The server details page in the web-based GUI shows information about server-related resources, including storage system disks that are associated with the volumes that are assigned to the server. A Performance tab shows performance information for SAN Volume Controller, Storwize V7000, and Storwize V7000 Unified storage virtualizers.
        Although performance information for disks is available only for these storage virtualizers, the Performance tab might be displayed for other storage systems. The Performance tab cannot show disk information for other storage systems.


        When reconfiguring a running monitoring agent, the agent cannot be restarted to use the new configuration

        The Tivoli Storage Productivity Center Monitoring Agent can be used by the Tivoli Enterprise Monitoring Server to monitor systems in your enterprise. This monitoring agent is an optional program that you can install and use in your enterprise. You can reconfigure a monitoring agent, if necessary, by using the Tivoli Enterprise Monitoring Services Console. If the monitoring agent is running when you reconfigure an agent, the agent must be restarted for the new configuration to take effect. If the agent is running, you are asked if you want to restart it. However, the restart operation fails. If errors are returned that indicate the agent was not stopped and started, use the Tivoli Enterprise Monitoring Services Console to manually stop and then start the monitoring agent.

        Tivoli Storage Productivity Center cannot recognize SAN Volume Controller entities that return online

        Due to limitations in the native API of the Storwize family of devices, Tivoli Storage Productivity Center cannot recognize when SAN Volume Controller entities, such as vdisks, mdisks, mdiskgroups return online after being offline.  

        Tivoli Storage Productivity Center is informed when entities fail or go offline.

        On AIX operating systems, if the language is set to FR_FR, text might not appear correctly on some installation pages

        On AIX operating systems, if the language is set to FR_FR, the Welcome page and the Single Server Installation Information page may not display correctly. For example, text might be truncated or there might not be enough space between sentences.

        Default Scan alert not showing any resource bound to it

        If a scan targets multiple resources and fails on one or more of those resources, the Resource column will be blank or will display only one of the failing resources. To see status for all the resource targets for the scan, use the stand-alone GUI. In the navigation tree, click Tivoli Storage Productivity Center > Monitoring > Scans > TPCUser.Default Scan to view the scan definition panel and click View Job History to see the Job Management page.

        Tivoli Storage Productivity Center data is not displayed on IBM Tivoli Monitoring: Tivoli Enterprise Portal desktop client in a distributed configuration

        In some cases, the workspaces of the IBM Tivoli Monitoring Agent for Tivoli Storage Productivity Center do not display in the Tivoli Enterprise Portal (TEP) desktop client when the Tivoli Monitoring Agent is installed on the same server as the Tivoli Enterprise Monitoring Services, and the Tivoli Enterprise Portal server is installed on a different server. To resolve this, install the TEP user interface extension from the Tivoli Monitoring Agent package on the same machine that the TEP server is installed on.

        Tivoli Storage Productivity Center uninstallation hangs during DB2 uninstallation

        The Tivoli Storage Productivity Center uninstaller might hang while you are removing the database repository. This problem occurs in Windows environments. The DB2 service does not stop in a timely manner. As a result, the uninstallation hangs while you are waiting for the DB2 service to stop.



        To resolve this issue:
        1. On the Windows server, go to Control Panel > Administrative Tools.
        2. Open Services.
        3. Right-click the DB2 service (for example, DB2 - DB2COPY1 - DB20), and select Properties.
        4. In the General tab, use the Path to executable value to identify the location of the DB2 executable file: db2syscs.exe. Close Services.
        5. Start the Windows Task Manager.
        6. In the Processes tab, select the db2syscs.exe file.
        7. Click End Process. The DB2 service stops, and the Tivoli Storage Productivity Center uninstallation continues.
        8. When the uninstallation is complete, restart the Windows server.

        Data displayed in other Tivoli products uses older data type labels

        When Tivoli Storage Productivity Center data is displayed in other Tivoli products, such as Tivoli Business Service Manager and Tivoli Application Dependency Discovery Manager, those applications use incorrect labels for some data types. The incorrect labels are from Tivoli Storage Productivity Center version earlier than V5.2.

        Other Tivoli applications might also use GB or MB capacity values rather than GiB or MiB, which Tivoli Storage Productivity Center V5.2 and later use.

        Examples:
        Pre-TPC5.2.x LabelTPC 5.2.x Label
        Volume Group CapacityPool Capacity
        Volume Group Freespace Available Pool Space
        Allocated CapacityAssigned Volume Space
        Available CapacityUnassigned Volume space


        Installation fails on Windows 2008 R2 in Russian language

        The Tivoli Storage Productivity Center installation fails on Windows 2008 R2 on a Russian language server. This is caused by a known DB2 issue.

        Total Capacity statistic in Tivoli Common Reporting reports is incorrect in some cases

        If a group includes a volume that is configured as back-end storage for a storage virtualizer, the Total Capacity value for that group that is displayed Tivoli Common Reporting reports might not be correct.

        Linux file system capacity is reported differently by Tivoli Storage Productivity Center and TADDM

        The capacity of Linux file systems is reported differently by Tivoli Storage Productivity Center and Tivoli Application Dependency Discovery Manager. The capacity value reported by Tivoli Storage Productivity Center is generally very similar to the value reported by the Linux operating system.

        APAR IC98638: Information Center incorrectly references the Configuration Utility

        In the IBM Tivoli Storage Productivity Center V5.2 and 5.2.1, the Configuration Utility and Configure Devices functions were moved from the stand-alone GUI to the web-based GUI. You can view a list of functions that were moved to the web-based GUI here:
        http://www.ibm.com/support/knowledgecenter/SSNE44_5.2.1/com.ibm.tpc_V521.doc/tpch_r_ui_changes_v52.html

        The following functions are no longer available in the stand-alone GUI:

        Viewing reports and topology for the XIV system environment
        To view the Tivoli Storage Productivity Center reports and topology for the XIV system environment, complete the following steps:
          1. Start the web-based GUI.
          2. In the navigation pane, select Storage Resources > Storage Systems.
          3. Click Add Storage System.
          4. Click the XIV icon.
          5. In the Add Storage System wizard, add the storage system that you want to monitor.
          6. After you add the XIV system, an automatic discovery and probe are started.
          7. View the reports and topology for the XIV system in Tivoli Storage Productivity Center.

        Error message GUI8293E is no longer valid
        Error message GUI8293E is no longer valid and will be removed in a future release. Disregard any references to the Configuration Utility.

        User account is locked after the DS Storage manager password for the DS8000 HMC is
        changed
        To resolve this, follow these steps to update the password for the element manager. If the passwords for multiple element manager users have changed, you must update the password for each user.
          1. Start the Tivoli Storage Productivity Center web-based GUI.
          2. In the navigation pane, select Storage Resources > Storage Systems.
          3. Right-click the DS8000 and select Open Storage System GUI.
          4. Log in to the IBM System Storage DS8000 Sign On panel and update the user password. Follow the instructions provided in the DS8000 Information Center:
        http://publib.boulder.ibm.com/infocenter/dsichelp/ds8000ic/index.jsp?topic=%2Fcom.ibm.storage.ssic.help.doc%2Ff2c_polcybasicusrmodfy_070511a.html

        APAR IC99222: Stop all jobs and reboot servers before upgrading Tivoli Storage Productivity Center

        Follow these steps before upgrading Tivoli Storage Productivity Center:

        1. Stop all jobs including performance monitor jobs, system and fabric probe jobs, scan jobs, and other probe jobs.

        2. If possible, reboot the Tivoli Storage Productivity Center servers. This will stop any remaining Tivoli Storage Productivity Center Java processes that might not stop in a timely manner. If a reboot is not possible, stop and restart the Tivoli Storage Productivity Center server service. It is important that the Tivoli Storage Productivity Center Device server stops and restarts cleanly. If this does not occur, a server reboot might be required.

        To track the status and resolution of this APAR, see http://www.ibm.com/support/docview.wss?uid=swg1IC99222.


        APAR IC99541: Error message BPCUI0292E has been updated

        The explanation and action sections of this message have been updated:

        Explanation
        The Tivoli Storage Productivity Center server is unable to contact the IP address or host name of the resource. This problem might occur if the local area network is down, the ping (ICMP) command is failing, or a firewall is preventing communication between the server and the resource.

        Action
        Verify that the IP address or host name of the resource is valid. Verify that the local area network is available. Verify by using the ping (ICMP) command that the resource is reachable from the TPC server. Ensure that a firewall is not preventing network access. Ensure that the Tivoli Storage Productivity Center server is running properly. Try to add the resource again.

        To track the status and resolution of this APAR, see http://www.ibm.com/support/docview.wss?uid=swg1IC99541.

        Error SRV0853E is displayed when you try to log in to the stand-alone GUI

        In some cases, when you try to log in to the stand-alone GUI, you get a SRV0853E error message. You see an error similar to the following error in the Data Server log file (<TPC_installation_directory>\data\log\ServerTrace.log):

        2016-10-18 13:14:23.931+0200 EXCEPTION
          java.lang.reflect.UndeclaredThrowableException
        at com.sun.proxy.$Proxy5.authenticate(Unknown Source)
        at com.tivoli.itsrm.server.SingleSignonHndlr.authenticateUserOrToken(SingleSignonHndlr.java:409)
        at com.tivoli.itsrm.server.SingleSignonHndlr.handle(SingleSignonHndlr.java:141)
        at com.tivoli.itsrm.server.RequestManager$RmThread.run(RequestManager.java:501)
        Caused by: [SOAPException: faultCode=SOAP-ENV:Server; msg=java.lang.IllegalArgumentException: Illegal daylight saving value: 0]
        at org.apache.soap.providers.RPCJavaProvider.invoke(Unknown Source)
        at com.tivoli.sanmgmt.middleware.data.RPCSecureJavaProvider.invoke(RPCSecureJavaProvider.java:172)
        at org.apache.soap.server.http.RPCRouterServlet.doPost(Unknown Source)
        at com.tivoli.sanmgmt.middleware.TSNMServiceManager.doPost(TSNMServiceManager.java:469)
        at javax.servlet.http.HttpServlet.service(HttpServlet.java:595)
        at javax.servlet.http.HttpServlet.service(HttpServlet.java:668)
        at com.ibm.ws.webcontainer.servlet.ServletWrapper.service(ServletWrapper.java:1275)
        at com.ibm.ws.webcontainer.servlet.ServletWrapper.handleRequest(ServletWrapper.java:766)
        at com.ibm.ws.webcontainer.servlet.ServletWrapper.handleRequest(ServletWrapper.java:472)
        at com.ibm.ws.webcontainer.filter.WebAppFilterManager.invokeFilters(WebAppFilterManager.java:1101)
        at com.ibm.ws.webcontainer.servlet.CacheServletWrapper.handleRequest(CacheServletWrapper.java:81)
        at com.ibm.ws.webcontainer.WebContainer.handleRequest(WebContainer.java:912)
        at com.ibm.ws.webcontainer.osgi.DynamicVirtualHost$2.run(DynamicVirtualHost.java:262)
        at com.ibm.ws.http.dispatcher.internal.channel.HttpDispatcherLink$TaskWrapper.run(HttpDispatcherLink.java:938)
        at java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1157)
        at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:627)
        at java.lang.Thread.run(Thread.java:798)  com.tivoli.itsrm.server.RequestManager$RmThread run RequestHandler0

        This error occurs because the Java Runtime Environment (JRE) does not comply with Daylight Saving Time (DST). To fix this problem, do one of the following actions:

        Limitations and known issues when using Tivoli Storage Productivity Center with VMware vSphere


        The following limitations and known issues can occur when you use Tivoli Storage Productivity Center with VMware vSphere:

        Following redeployment, the Tivoli Storage Productivity Center build version does not match the version number of the vSphere Web Client extension

        After you redeploy the vSphere Web Client extension, the Tivoli Storage Productivity Center build version might not match the version number of the vSphere Web Client extension. To resolve this issue, complete the following steps to redeploy the extension:

        1. On the vSphere Web Client computer that connects to the vCenter Server system where the extension is installed, go to the plug-in directory:
        • On Windows operating systems:
          • C:\ProgramData\VMware\vSphere Web Client\vc-packages\vsphere-clientserenity
        • On Linux operating systems:
          • /var/lib/vmware/vsphere-client/vc-packages\vsphere-client-serenity

        2. Delete the packages for the vSphere Web Client extension. Package files use the following naming convention: com.ibm.tpc-TPC-build-number.

        3. Delete the TPCServerConfiguration.properties file. The file is stored in the following location:
        • On Windows operating systems:
            %PROGRAMDATA%\IBM\TPC

            For example, C:\ProgramData\IBM\TPC\ or %ALLUSERSPROFILE%\IBM\TPC
            For example, C:\Documents and Settings\All Users\IBM\TPC\
        • On Linux operating systems:
            /opt/IBM/TPC

        4. Redeploy the vSphere Web Client extension.

        5. Restart the VMware vSphere Web Client service.

        6. Log in to the vSphere Web Client. From the vSphere Web Client Home tab, in the Administration section, click the IBM Tivoli Storage Productivity Center icon. Confirm that the Tivoli Storage Productivity Center build version matches the version number of the vSphere Web Client extension.

        Disable Windows User Access Control to edit configuration files

        On Windows installations, if you installed Tivoli Storage Productivity Center by using a domain user account, you must disable User Account Control to edit the vasa_filter.properties file.

        Provisioning with VMware datastore creation to a clustered ESX 5.1 is partially complete
        If you provision storage with datastore creation to two clustered ESX 5.1 hypervisors by using the vSphere Web Client extension, the datastore is not assigned to the second hypervisor. The datastore is not assigned because of a LUN snapshot issue in VMware vCenter Server.

        To learn how to resolve this issue, go to the VMware Knowledge Base at http://kb.vmware.com/selfservice. Search for vSphere handling of LUNs detected as snapshot LUNs (1011387).

        vCenter 5.1 Server does not display events from the Tivoli Storage Productivity Center VASA provider

        The SMS log might show that events were received from the Tivoli Storage Productivity Center VASA provider and an attempt was made to post them to the vCenter 5.1 Server.

        In the vSphere Client, click Home > Management > Events. The event from the VASA provider is not logged. In the vSphere Web Client, click Home > Monitoring > Event Console. The event from the VASA provider is not displayed.

        Upgrade to vCenter 5.5 Server to resolve this issue.

        Storage DRS calls fail for datastore clusters with file system storage

        When a Tivoli Storage Productivity Center VASA provider is added to the vCenter 5.1 Server, a datastore cluster that contains a NetApp datastore and an IBM® Scale Out Network Attached Storage datastore fails to log Storage DRS calls. Upgrade to vCenter 5.5 Server to resolve this issue.

        vCenter 5.1 Server does not send a storage DRS request to the Tivoli Storage Productivity Center VASA provider

        In a datastore clustered NFS environment, vCenter 5.1 Server does not send a Storage DRS request to the Tivoli Storage Productivity Center VASA provider. System Capability and Storage Provider Namespace values are populated correctly. Upgrade to vCenter 5.5 Server to resolve this issue.

        Tivoli Storage Productivity Center VASA provider alarms might be displayed in the Events panel

        Tivoli Storage Productivity Center alerts that are sent as alarms to the vCenter 5.1 Server from the Tivoli Storage Productivity Center VASA provider might be displayed in the Events panel, instead of the Alarms panel. Upgrade to vCenter 5.5 Server to resolve this issue.

        Tivoli Storage Productivity Center VASA provider SpaceCapacity alarm might behave inconsistently

        If a VASA SpaceCapacity alarm is return to a LUN that does not belong to a datastore, an event is displayed in the vCenter 5.1 Server. If the LUN belongs to a datastore, two non-relevant events are displayed. Upgrade to vCenter 5.5 Server to resolve this issue.

        Alerts omit the storage provider name

        In the vSphere Client, the Events tab shows the Storage provider name that is associated with an alert. In the vSphere Web Client, the Events Console omits the Storage provider name.

        Alarms with the StorageFileSystem entity type are flagged as unknown

        For the Tivoli Storage Productivity Center VASA provider alarms on StorageFileSystem objects that are returned to the vCenter 5.1 Server, an unknown vCenter identifier is displayed. Upgrade to vCenter 5.5 Server to resolve this issue.

        Delay in refreshing Tivoli Storage Productivity Center VASA provider data in Storage Reports after synchronization

        VASA provider data can take some time to be displayed in Storage Reports after a successful synchronization. Upgrade to vCenter 5.5 Server to resolve this issue.

        The Volume Not Found alert might not be displayed in vCenter Server

        The vCenter Server SMS log shows a generated alert, but the alert is not displayed on the vSphere Client or the vSphere Web Client. Upgrade to vCenter 5.5 Server to resolve this issue.

        The Tivoli Storage Productivity Center VASA provider does not register automatically on vCenter Server

        When an exception occurs while querying an existing Tivoli Storage Productivity Center VASA provider by using the Storage Monitoring Service API, the automatic registration of the VASA provider may not succeed.

        Storage View reports on vCenter Server take a long time to refresh

        If you configure VASA providers on the vCenter Server, it might take a long time for the Storage View reports to refresh. This issue is more likely to occur if you have more than one VASA provider configured.

        As a work around, configure only one VASA provider on the vCenter Server.

        The vSphere Web Client extension recovery after the vSphere Web Client server restarts

        A vCenter Server provisioning task might stay in a Queued state during the approval process by the Tivoli Storage Productivity Center administrator. During this time, the vSphere Web Client server or the host machine might be restarted.

        The vSphere Web Client can close a connection to the vCenter Server after a time-out. The default for this time-out is 120 minutes.

        If a time-out occurs, the vSphere Web Client extension for Tivoli Storage Productivity Center restores the connectivity to the vCenter Server and Tivoli Storage Productivity Center when a user logs in to the vSphere Web Client. The status of the provisioning task is updated based on the status of the task in Tivoli Storage Productivity Center.

        To start the recovery process, log in to the vSphere Web Client and go to one of the following panels in the vSphere Web Client extension:
        • Tivoli Storage Productivity Center provisioning
        • Tivoli Storage Productivity Center saving configuration information
        • Tivoli Storage Productivity Center storage system metrics

        The All TPC Actions string is not translated in some locales

        Due to an error in the translation process, the All TPC Actions string is not translated in double-byte locales.

        Deploying the vSphere Web Client extension on vCenter Server 5.5 fails on Windows 2008 or Linux

        If you deploy the vSphere Web Client extension from a Tivoli Storage Productivity Center server onto a vCenter Server 5.5 that is installed on Windows 2008 or Linux, the deployment fails. The following message is displayed:
        BTAVM2244E The remote registration of the vSphere Web Client extension for Tivoli Storage Productivity Center did not complete.

        The deployment fails due to a handshake issue with the vSphere Client, vSphere PowerCLI, and vCenter Server 5.5.

        To learn how to resolve this issue, go to the VMware Knowledge Base at
        http://kb.vmware.com/selfservice. Search for vSphere Client and vSphere PowerCLI
        may fail to connect to vCenter Server 5.5 due to a Handshake failure (2049143).

        [{"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"--","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF033","label":"Windows"}],"Version":"5.2.1","Edition":"All Editions","Line of Business":{"code":"LOB26","label":"Storage"}},{"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":null,"Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF033","label":"Windows"}],"Version":"5.2.1","Edition":"All Editions","Line of Business":{"code":"LOB26","label":"Storage"}}]

        Document Information

        Modified date:
        22 February 2022

        UID

        swg21659363