IBM Support

Received a failure while appling fixes

Technote (FAQ)


Question

Why is the linkedit for CECT2CD failing during the apply of a fix? The received message is...

IEW2690E 3530 ONE OR MORE FIELD DESCRIPTORS IN GOFF RECORD 2432 WITHIN
MEMBER CECCT2CD IDENTIFIED BY DDNAME SMPWRK3 ARE NOT VALID. ERRORID = 22.
IEW2307E 1032 CURRENT INPUT MODULE NOT INCLUDED BECAUSE OF INVALID DATA.

Answer

This instance was because the file was not transferred from the ftp site a binary. Try downloading the files again and ensure that the session was put into BIN mode before transferring the files.

Document information

More support for: InfoSphere Classic Federation Server for z/OS
General issues

Software version: All Versions

Operating system(s): z/OS

Software edition: All Editions

Reference #: 1650178

Modified date: 30 September 2013