IBM Support

Ontape restore failed with SQLCODE -27002

Troubleshooting


Problem

Ontape process fails to connect to the Informix server while performing restore and returns error -27002 (No connections are allowed in quiescent mode).

Symptom

You took an ontape backup on a lower version of Informix and performing ontape restore on a higher version. The restore is failing with following error:

Physical restore failed - could not fork server connection, SQLCODE -27002

Cause

There is a mismatch between Informix versions. You must use the same Informix version for backup and restore.

Important: This is only one possible cause of the problem. If this document does not give you what you need then search for other documents with the same problem.

[{"Product":{"code":"SSGU8G","label":"Informix Servers"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"--","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF022","label":"OS X"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"12.1;11.7;11.5;11.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
16 June 2018

UID

swg21642825