Ontape restore failed with SQLCODE -27002

Technote (troubleshooting)


Problem(Abstract)

Ontape process fails to connect to the Informix server while performing restore and returns error -27002 (No connections are allowed in quiescent mode).

Symptom

You took an ontape backup on a lower version of Informix and performing ontape restore on a higher version. The restore is failing with following error:

Physical restore failed - could not fork server connection, SQLCODE -27002


Cause

There is a mismatch between Informix versions. You must use the same Informix version for backup and restore.

Important: This is only one possible cause of the problem. If this document does not give you what you need then search for other documents with the same problem.


Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Informix Servers

Software version:

11.1, 11.5, 11.7, 12.1

Operating system(s):

AIX, HP-UX, Linux, Mac OS X, Solaris, Windows

Reference #:

1642825

Modified date:

2013-08-01

Translate my page

Machine Translation

Content navigation