Long time (several minutes) for 'open' icon to be active after launching "Data Entry - Reported Values"

Technote (troubleshooting)


Problem(Abstract)

User clicks "Company - Data Entry - Reported Values". The new screen appears, where the user can enter their parameters. However, it takes several minutes for the 'open' icon to become active.

Cause

Client device does not have ability to connect to the internet, and therefore Microsoft .NET certificate checking (for the Controller client) causes the code execution to hang for several minutes.

Resolving the problem

There are several methods to solve the problem:

  • Method #1 - Typically easiest for most customers - Disable .NET certificate checking (disable 'CRL verification') for all applications
  • Method #2 - Disable .NET certificate checking (over the Internet) only for Controller/Excel.
  • Method #3 - Allow the clients and application server to access the internet

TIP: For more details on the above, see separate IBM Technote #1347312.

Related information

1347312 - Very poor performance of Controller (8.2 or l

Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Cognos Controller
Controller

Software version:

10.1.1

Operating system(s):

Windows

Reference #:

1641989

Modified date:

2013-06-26

Translate my page

Machine Translation

Content navigation