KMSPDCOL- Problem Determination Data Collection for Tivoli Monitoring z/OS products

Preventive Service Planning


Abstract

Tool to collect Tivoli Monitoring product on z/OS, similar to pdcollect on the distributed platform.

Content

KMSPDCOL is shipped with the Tivoli Management Server (HKDS6xx) product in &thilev.TKANSAM. During ICAT and PARMGEN process, KMSPDCOL is copied into &rhilev.&rte.RKANSAM.

Prerequisite to using KMSPDCOL, you need to have SDSF or you can copy the started task output into a dataset

1. From TSO:

EX '&rhilev.&rte.RKANSAM(KMSPDCOL)' 'JOBNAME(started task name) JOBNO(job number)'

or

EX '&rhilev.&rte.RKANSAM(KMSPDCOL)' 'JOBOUT(dataset of your started task output)'

where started task name and job number is the started task name and started task number of the agent or TEMS having issues and dataset of your started task output is the dataset you copied the problem agent or TEMS's logs into.

2. RESPONSE WILL SHOW THE FOLLOWING:


***************************************************************

THIS CLIST WILL COLLECT DIAGNOSTIC INFORMATION FROM
THE SYSTEM ON WHICH IT IS EXECUTED.

THE MINIMUM DATA COLLECTED IS:

- SYSTEM CONFIGURATION
- NETWORK INFORMATION (OUTPUT FROM NETSTAT ALLCONN COMMAND)
- OUTPUT FROM THE SPECIFIED JOB
- QA1 FILES (IF REQUESTED)
- THE CONTENTS OF THE FOLLOWING LIBRARIES:
- &RHILEV.&SYS.RKANCMD
- &RHILEV.&SYS.RKANCMDU
- &RHILEV.&SYS.RKANPAR
- &RHILEV.&SYS.RKANPARU

INCLUDE QA1 FILES? (Y/N): <==== If you want to collect the //QA1 files?
3. RESPONSE

ALL REQUIRED VARIABLES WERE FOUND

RHILEV = YOUR.RHILEV
RVHILEV = YOUR.RVHILEV
BASEHLEV = YOUR.BASEHLEV
SYS = YOURSYS

NO OPSLOG DATASETS FOUND

CREATING DATASET: USERID.PDCOLLCT.DAT

COMPRESSING DATASETS...

**********************************************************
THE FOLLOWING DATASET
'USERID.PDCOLLCT.DAT'
CONTAINS THE PDCOLLECT DIAGNOSTIC INFORMATION. PLEASE
FORWARD THIS BINARY FILE TO YOUR IBM SUPPORT REPRESENTATIVE.
**********************************************************

4. USERID.PCOLLCT.DAT can be ftp'd in binary format to your PMR.

Cross reference information
Segment Product Component Platform Version Edition
Systems and Asset Management Tivoli OMEGAMON XE for CICS on z/OS 4.2.0, 4.1.0, 5.1.0
Systems and Asset Management Tivoli OMEGAMON XE on z/OS 4.1.0, 4.2, 5.1.0
Systems and Asset Management Tivoli OMEGAMON XE for CICS TG on z/OS 4.2.0, 5.1.0
Systems and Asset Management Tivoli OMEGAMON XE for DB2 Performance Expert for z/OS 4.2.0, 4.1.0, 5.1.0, 5.1.1
Systems and Asset Management Tivoli OMEGAMON XE for DB2 Performance Monitor for z/OS 5.1.0, 5.1.1
Systems and Asset Management Tivoli OMEGAMON XE for IMS on z/OS 4.2.0, 4.1.0, 5.1.0
Systems and Asset Management Tivoli OMEGAMON XE for Mainframe Networks 4.2.0, 4.1.0, 5.1.0
Storage Management Tivoli OMEGAMON XE for Storage on z/OS 4.2.0, 4.1.0, 5.1.0
Systems and Asset Management Tivoli OMEGAMON XE for Messaging for z/OS 6.0.1, 6.0.0, 7.0, 7.0.1, 7.1.0

Rate this page:

(0 users)Average rating

Document information


More support for:

Tivoli Monitoring Version 6

Software version:

6.2.2, 6.2.3, 6.2.3.1, 6.2.3.2, 6.2.3.3, 6.2.3.4, 6.3, 6.3.0

Operating system(s):

OS/390, z/OS

Reference #:

1635639

Modified date:

2014-03-21

Translate my page

Machine Translation

Content navigation