How to maintain direction of assembly while using AUTOSAR in Rational Rhapsody

Technote (FAQ)


How do you maintain direction of assembly in AUTOSAR using JAVA API in IBM Rational Rhapsody?


You would like to use Java Application Programming Interfaces (API) code to automate the manual task of maintaining the direction of assembly in AUTOSAR within Rational Rhapsody in C.


In order to maintain the direction of assembly in AUTOSAR in Rational Rhapsody in C, you can use the attached API by following the steps below:

  1. Extract the attached archive to the Profiles folder of your Rhapsody installation

  2. Open the Rational Rhapsody model

  3. Click on File > Add Profile To Model and select from under the ContiProfile folder. The plugin will be automatically initialized and a confirmatory text can be seen in Rhapsody's log window.

  4. Click on Tools > UpdateConnectorDirection to invoke the Plugin as indicated in the log window.


All source code and/or binaries attached to this document are referred to here as "the Program". IBM is not providing program services of any kind for the Program. IBM is providing the Program on an "AS IS" basis without warranty of any kind. IBM WILL NOT BE LIABLE FOR ANY ACTUAL, DIRECT, SPECIAL, INCIDENTAL, OR INDIRECT DAMAGES OR FOR ANY ECONOMIC CONSEQUENTIAL DAMAGES (INCLUDING LOST PROFITS OR SAVINGS), EVEN IF IBM, OR ITS RESELLER, HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.