IBM Support

AgFileSystem monitoring codes

Question & Answer


Question

Error codes for RSCT IBM.AgFileSystem resources are logged in the syslog. What are the possible error codes and their meaning?

Cause

Consider the following syslog entry/example :
Mar 8 15:37:38 mynode StorageRM[25407]: (Recorded using libct_ffdc.a cv 2):::Error ID: :::Reference ID: :::Template ID: 0:::Details File: :::Location: RSCT,AgFileSystem.C,1.162,2636 :::STORAGERM_MESSAGE_ST#012StorageRM informational message#012DIAGNOSTIC EXPLANATION#0122668-047 Monitoring operation on the device (/dev/sas_vg/dwh_prod_lv with MntPt=/DWH/PROD) has failed with code 1 in the class "IBM.AgFileSystem"#012

Answer

The file system was monitored and returned a failure with code 1. This means the file system was monitored as un-mounted.

Here are the possible "code" values for the monitoring of AgFileSystem class resources :

Code
Monitoring result
0
Success
1
Not mounted
2
[This code is not currently used]
3
Mounted on different device
4
No mount point
5
Unknown mount status
6
I/O failed

[{"Product":{"code":"SSRM2X","label":"Tivoli System Automation for Multiplatforms"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"--","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"}],"Version":"3.1;3.2;3.2.1;3.2.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]