Translation using gntxeng.exe failed with error 80040702 and 80010105

Technote (troubleshooting)


Problem(Abstract)

Audit error 1-6-2001
Translation using gntxeng.exe failed with error 80040702 and 80010105
EDIFACT data with 8 byte date

Symptom

When processing EDIFACT data with 8 byte date the data receives audit error 1-6-2001, Translation using gntxeng.exe failed with error 80040702 and 80010105.


Cause

When using pass-thru processing the element format on the UNB04 in the transaction map was set incorrectly. While the field has a min/max of 6/8, the format was set to YYMMDD.

Environment

Gentran:Server for Windows Application Integrator Mapping

Resolving the problem

Verify the UNB04 in the transaction map being used for pass thru mapping, and change if necessary to YYYYMMDD to match the EDIFACT data being processed.