EPILOG EDS unusable

Technote (troubleshooting)


Problem(Abstract)

Upgrade of OMEGAMON XE on z/OS. EPILOG get error message:
Message EC936: WARNING: EPILOGC SKIPPING UNUSABLE EDS

Symptom

EPILOG EDS is unusable. EPILOG output shows following message:

rtename R= epilogproc IEFC452I epilogproc - JOB NOT RUN - JCL
ERROR


Cause

Before upgrade, customer was not using System Variables for EPILOG. After upgrade, customer was using System Variables. The LOAD statement in one of the EPILOG jobs, before the upgrade, included quotes, as follows:

// LOAD='OMEGAMON.systemname.RKANMOD',
where systemname is replaced by the system name.
During the upgrade, EPILOG was changed to use System Variables and the statement now looks as follows
// LOAD='OMEGAMON.&SYSNAME..RKANMOD',
MVS rules require no quotes if PROC statement will contain a system
variable.


Resolving the problem

Remove the quotes around the library name, as follows:


// LOAD=OMEGAMON.&SYSNAME..RKANMOD,

Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Tivoli OMEGAMON II for MVS

Software version:

All Versions

Operating system(s):

z/OS

Reference #:

1625678

Modified date:

2014-01-13