When opening a folder attached to a workflow, the viewer displays "Sorry an error occurred" in IBM Content Navigator.

Technote (troubleshooting)


Problem(Abstract)

In IBM Content Navigator (ICN), the error "Sorry an error occurred" [sic], appears when attempting to open a folder in the attachments tab of a workflow.

Symptom

The error as described above appears in the folder view in ICN. No errors or warnings are logged to the application server's files.


Cause

This may be caused by a property mis-configuration whereby the symbolic name and the label name of the object store do not match. As the workflow step uses the label name instead of the symbolic name, the mismatch throws the error.

Diagnosing the problem

Check the symbolic and label names of the object stores for a mismatch.

Resolving the problem

To resolve the issue, modify the symbolic name and label name of the object store to ensure that they are identical. Once they have been altered, retry the operation.

Product Alias/Synonym

ICN

Rate this page:

(0 users)Average rating

Document information


More support for:

Content Navigator

Software version:

2.0, 2.0.0.1, 2.0.1

Operating system(s):

AIX, Linux, Linux on System z, Windows

Reference #:

1625108

Modified date:

2013-09-02

Translate my page

Machine Translation