Skip to main content

Why is the size of some Connect:Direct modules reported differently in the startup output to the size that is listed in the LINKLIB?


Technote (troubleshooting)


Problem(Abstract)

There is a difference in the way the size of some modules are reported in IBM Sterling Connect:Direct during startup as opposed to the size reported in the LINKLIB. For example,



In LINKLIB:

DMGSAF , , 00005918 000184 00 31 24



In the C:D Startup:

DMGSAF EP=80042000 SIZE=00006000

Resolving the problem

Check if the LINKLIB is a PDSE or a PDS dataset; the module size in a PDSE LINKLIB is reported differently to the module size in a PDS LINKLIB.
Note: this is purely cosmetic and it will not affect product functionality.

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.