Technote (troubleshooting)
Problem(Abstract)
Interchange Browser not displaying data older 3 years, Commands > SORT > FROM Date/time not functioning
Cause
APAR IC89443, RTC 361996
Resolving the problem
Defect corrected in Version 5.5 EDIMGR.EXE compiled 01/16/2013
This program fix is available from the Gentran Support team.
To apply the fix,
a. Stop DirectorExecutive
b. Navigate to the BIN directory for Director
c. Create a folder named EDIMGR
d. Move the current EDIMGR.EXE from the BIN to this new EDIMGR folder, this would be used if a restore effort is needed.
e. Save the new delivered EDIMGR.EXE to the BIN
f. Restart DirectorExecutive
Product Alias/Synonym
GDW
Rate this page:
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.