Inconsistencies found between execution records

Technote (troubleshooting)


Problem(Abstract)

Previous Results from a Test Suite Execution Record lists the same test case executed multiple times when using IBM Rational Quality Manager (RQM).

Symptom

Multiple test case executions in test suite.


Cause

One possible cause for this problem is that a command line adapter (CLA) script is executed from a test case and the command line adapter associated with the test script is running multiple times.

Environment

This issue was reported with the command line adapter running on RHEL 5.3

Diagnosing the problem




  • On UNIX run ps aux | grep adapter and look for multiple PIDs running for the same adapter.

  • On Microsoft Windows, use the Task Manager to list processes or use a utility such as Windows Sysinterals Process Explorer.

Leverage the Jazz Community

The Jazz based products have an active community that can provide you with additional resources. Browse and contribute to the User forums, contribute to the Team Blog and review the Team wiki.

Review technote 1319600: Leveraging the Jazz Community on Jazz.net for details.

Resolving the problem

Kill any additional process to ensure the command line adapter instance is only running once.