IBM Support

Starting the RTC WebSphere profile results in the "ADMU7704E:" error reported in the WebSphere startServer.log file

Troubleshooting


Problem

Attempts to start the IBM Rational Team Concert WebSphere profile results in the error "ADMU7704E: Failed while trying to start the Windows Service associated with server: server1;".

Symptom

You see one or more of the following errors while starting the Rational Team Concert WebSphere profile:

ADMU0116I: Tool information is being logged in file $WEBSPHERE_HOME\AppServer\profiles\CLM1\logs\server1\startServer.log

ADMU7701I: Because server1 is registered to run as a Windows Service, the request to start this server will be completed by starting the associated Windows Service.

ADMU7704E: Failed while trying to start the Windows Service associated with server: server1;probable error executing WASService.exe:

Starting Service: adtclmamr015Node01 Timed out waiting for service to respond to command, after 1200 seconds.
Failed to start service, or timed out while waiting for start to complete. Check the logs for details.

Cause

The previous profile shutdown was improper. There is a high probability that the server1.pid file has not been deleted.

Diagnosing The Problem

Check if the server1.pid file is still located in the following location:

<WebSphere_installation>/AppServer/profiles/<Profile_Name>/logs/server1/server1.pid

If present, apply solution below to resolve.

Resolving The Problem

Delete the server1.pid. file and restart the profile.

WORKAROUND:

Restart the profile using the command line utility:

  1. Start a command prompt
  2. Navigate (cd) to the <WebSphere_installation>/AppServer/bin directory
  3. Run the command:

    startServer.bat server -profileName <Name_of_the_RTCProfile>

[{"Product":{"code":"SSUC3U","label":"IBM Engineering Workflow Management"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Web App Server","Platform":[{"code":"PF033","label":"Windows"}],"Version":"3.0;3.0.1;3.0.1.1;3.0.1.2;3.0.1.3;3.0.1.4;3.0.1.5;4.0;4.0.0.1;4.0.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]