Running a manual script that contains a keyword associated with a Rational Functional Tester script from Rational Quality Manager fails

Technote (troubleshooting)


Problem(Abstract)

When you run a manual script from IBM Rational Quality Manager that contains a keyword associated with an IBM Rational Functional Tester script, running the functional test script fails.

Symptom

Running a manual script that contains a keyword that is associated with a functional test script fails.


Cause

The path of the shared location in which the functional test script resides includes the project directory that contains the functional test script. Due to this, the path of the functional test script includes the project name twice.

Resolving the problem

The shared location path that is added to Rational Quality Manager should stop at a directory that is one level higher than the project directory in which the functional test script resides.