ITM 6: TACMD managesit does not correctly start/stop situations

Technote (troubleshooting)


Problem(Abstract)

This technote addresses an issue where situations are not correctly started or stopped on target systems even though the managesit command reports success.

Resolving the problem

This is a known defect under APAR IZ42007 when the agents are connecting through an RTEMS. In the short term, customers can use the "-n" switch to specify the TEMS name and get around this issue.

This is resolved in ITM 6.23 Fixpack 2 onwards.