Skip to main content

Alerts for Rule Message CGIS043I display the node name incorrectly.


Technote (troubleshooting)


Problem(Abstract)

All Control Center alerts (down or up) for Sterling B2B Integrator for perimeter server nodes are reading as
"node2" even when they should be reading "node1". We ran a report and noticed that the node name is also incorrect in the database.

Symptom

Sterling B2B Integrator node names are not showing correctly on node down or up alerts from Sterling Control Center.


Cause

This has been identified as a product defect under APAR IC88269

Resolving the problem

Apply the fix from APAR IC88269

Cross reference information
Segment Product Component Platform Version Edition
Commerce Sterling B2B Integrator Not Applicable HP-UX, i5/OS, IBM i, Linux, Solaris, Windows 5.2.4.1, 5.2.4, 5.2.3, 5.2.2, 5.2.1

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page: