Alerts for Rule Message CGIS043I display the node name incorrectly.

Technote (troubleshooting)


Problem(Abstract)

All Control Center alerts (down or up) for Sterling B2B Integrator for perimeter server nodes are reading as "node2" even when they should be reading "node1". A report shows that the node name is also incorrect in the database.

Symptom

Sterling B2B Integrator node names are not showing correctly on node down or up alerts from Sterling Control Center.


Cause

This has been identified as a product defect under APAR IC88269

Resolving the problem

Apply the Sterling Control Center maintenance that includes the fix from APAR IC88269

Cross reference information
Segment Product Component Platform Version Edition
Commerce IBM Control Center AIX, HP-UX, Linux, Solaris, Windows 5.4, 5.3

Document information


More support for:

Sterling B2B Integrator

Software version:

5.3, 5.4

Operating system(s):

AIX, HP-UX, Linux, Solaris, Windows

Reference #: