Technote (troubleshooting)
Problem(Abstract)
All Control Center alerts (down or up) for Sterling B2B Integrator for perimeter server nodes are reading as
"node2" even when they should be reading "node1". We ran a report and noticed that the node name is also incorrect in the database.
Symptom
Sterling B2B Integrator node names are not showing correctly on node down or up alerts from Sterling Control Center.
Cause
This has been identified as a product defect under APAR IC88269
Resolving the problem
Apply the fix from APAR IC88269
| Segment | Product | Component | Platform | Version | Edition |
|---|---|---|---|---|---|
| Commerce | Sterling B2B Integrator | Not Applicable | HP-UX, i5/OS, IBM i, Linux, Solaris, Windows | 5.2.4.1, 5.2.4, 5.2.3, 5.2.2, 5.2.1 |
Rate this page:
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.