CCNS018E Monitor rate out of compliance

Technote (troubleshooting)


Problem(Abstract)

Events CCNS018E Monitor out of Compliance and CCNS029I Monitor rate back in compliance occurs too often.

Symptom

Monitoring a Connect:Enterprise UNIX node with Sterling Control Center with a monitor rest time of three minutes.


Cause

This has been identified as a product defect under APAR IC88080

Diagnosing the problem

Many compliance error messages

Resolving the problem

Work around - Lower the monitor rest time to one minute.
Apply Sterling Control Center maintenance that includes APAR IC88080

Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Sterling Control Center

Software version:

5.3

Operating system(s):

AIX, HP-UX, Linux, Solaris, Windows

Reference #:

1618849

Modified date:

2012-12-20

Translate my page

Machine Translation