CDSPLMON Failure to send spool files


Technote (troubleshooting)


Problem(Abstract)

Following the upgrade from Connect:Direct i5/OS 3.5 to 3.7, the C:D Spool Monitor failed
to send spool files from the upgraded iSeries partition to another
iSeries partition. C:D Spool Monitor had previously been configured to
do this.

Symptom

Message ID . . . . . . : CPD0074

Message . . . . : Value '000001 ' for SPLFNUM exceeds 4 characters.

Cause

Command CDSPLAGENT variable is only 4 characters for SPLFNUM when it is being passed as 6.

Diagnosing the problem

View job log for CDSPLMON

Resolving the problem

Apply the maintenance for Connect:Direct i5/OS 3.7.00.

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.