CDSPLMON Failure to send spool files

Technote (troubleshooting)


Problem(Abstract)

Following the upgrade from Connect:Direct i5/OS 3.5 to 3.7, the C:D Spool Monitor failed
to send spool files from the upgraded iSeries partition to another
iSeries partition. C:D Spool Monitor had previously been configured to
do this.

Symptom

Message ID . . . . . . : CPD0074

Message . . . . : Value '000001 ' for SPLFNUM exceeds 4 characters.

Cause

Command CDSPLAGENT variable is only 4 characters for SPLFNUM when it is being passed as 6.

Diagnosing the problem

View job log for CDSPLMON

Resolving the problem

Apply the maintenance for Connect:Direct i5/OS 3.7.00.