Technote (troubleshooting)
Problem(Abstract)
Following the upgrade from Connect:Direct i5/OS 3.5 to 3.7, the C:D Spool Monitor failed
to send spool files from the upgraded iSeries partition to another
iSeries partition. C:D Spool Monitor had previously been configured to
do this.
Symptom
Message ID . . . . . . : CPD0074
Message . . . . : Value '000001 ' for SPLFNUM exceeds 4 characters.
Cause
Command CDSPLAGENT variable is only 4 characters for SPLFNUM when it is being passed as 6.
Diagnosing the problem
View job log for CDSPLMON
Resolving the problem
Apply the maintenance for Connect:Direct i5/OS 3.7.00.
Rate this page:
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.