INFORMATION SERVER: With multi-client installations, results in missing properties on DB2 connector

Technote (troubleshooting)


Problem(Abstract)

GUI for Connector (DB2) is missing the part for entering connection properties

Cause

GUI for Connector (DB2) is missing part for entering connection properties on a Windows client with both IS 8.1 fp2 (8.1.0.2) client and 8.7 Fp1 (8.7.0.1) client installed

Diagnosing the problem

This happena when IS 8.7 is installed and switching between clients using multi-client manager.

Resolving the problem

To resolve the Issue carry out one of the 3 options specified in the following technote:



http://www-01.ibm.com/support/docview.wss?uid=swg21450055


This is a problem in the Multi-client switcher.