Registry situations with OR operator not working

Technote (troubleshooting)


Problem(Abstract)

The Windows OS agent does not detect OR in the filter object and filters
only on the last OR predicate, ignoring the first two.

Symptom

Only the last OR is displayed


Cause

This has been identified as a product defect under APAR IV30796

Environment

Windows

Diagnosing the problem

The following tracing needs to be set:
Windows OS agent:
ERROR (UNIT:kraafmgr all er)(UNIT:kraadspt,Entry="sendDataToProxy" all er) (unit:kraafmgr all er)(UNIT:krandagt state er) (unit:kraadspt all er) (unit:kdsflt1 all er)(unit:kdsxoc2 all er)

KDS_TRACEFILTER=ALL

RTEMS that the agent connects to:
ERROR (unit:kpxrpcrq,Entry="IRA_NCS_Sample" state er)
IRA_DUMP_DATA="Y"
IRA_DUMP_MAX_ROWS="20"

Resolving the problem

This is working as designed. A work around is to change the situations for the Registry attribute group to a definition with a single set of filtering data.

Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Tivoli OMEGAMON XE for Distributed Systems
Windows

Software version:

06.2.2.0

Operating system(s):

Windows, Windows 2003 server

Reference #:

1615363

Modified date:

2013-09-23

Translate my page

Machine Translation

Content navigation