Configured DC not showing in the ITCAM MS

Technote (troubleshooting)


This document applies only to the following language version(s):

US English

Problem(Abstract)

After configuring the data collector it doesn't connect to the ITCAM managing server.

Symptom

## Using kernel.codebase for RMI file downloading
java.io.IOException: EDC5111I Permission denied. (errno2=0x5B450002)
at java.io.File.checkAndCreate(File.java:1380)
at java.io.File.createTempFile(File.java:1468)
at java.io.File.createTempFile(File.java:1504)


Cause

The WebSphere App Server could not write to the /tmp directory

Environment

z/OS

Diagnosing the problem

Look for these RACF errors in the SYSLOG
ICH408I USER(SYP5ACRU) GROUP(SYP5CFG ) NAME(WAS APPSVR CR ) 063
/products/TMPDIR/guid.lock CL(DIRACC )
FID(01C7D4F4D6D4F1005A13000002E70000) INSUFFICIENT AUTHORITY TO OPEN
ACCESS INTENT(-W-) ACCESS ALLOWED(OTHER R-X) EFFECTIVE UID(0000341001)
EFFECTIVE GID(0000309001)

Resolving the problem

Ensure the App Server can write to the tmp directory. In this case the user had modified the WebSphere TMPDIR to another location that the App Server didn't have permissions to.

Product Alias/Synonym

ITCAM ITCAMfAD ITCAM for App Diagnostics