XR_Freeze::WaitForSingleObject timed out error causes snapshot abort


Technote (troubleshooting)


Problem(Abstract)

"FBSS7011E" and "XR_Freeze::WaitForSingleObject timed out" errors during FastBack VSS flush

Symptom

The snapshot aborts 3 minutes after it was started.


Cause

Some VSS writers didn't freeze within 180 seconds.

Diagnosing the problem

The following errors are printed in the FastBack Client log:

E14.MULTIFLUSH : MultiFlush (EXTERNAL DLL): XR_Freeze::WaitForSingleObject timed out, writers did not freezed in 180 seconds
E18.MULTIFLUSH : MultiFlush_LoopAndLock: VSS_FREEZE_FAILURE
W12.MULTIFLUSH : MultiFlush_LoopAndLock: VSS flush FAILED

The following error appears in the FastBack Server technician log and the snapshot's event:

FBSS7011E VSS freeze failed on ClientName


Resolving the problem

Increase the VSS freeze timeout by adding the "timeout" parameter to FastBackClient.ini:


    [VSS]
    timeout = 360

The value of the parameter is in seconds.
After editing the FastBackClient.ini, restart the FastBack Client service.

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

Tivoli Storage Manager FastBack

Client


Software version:
All Supported Versions


Operating system(s):
Windows


Reference #:
1611519


Modified date:
2012-12-31

Translate my page

Content navigation