Problem

If there is enough space in the filesystem, but the error ADM2017C (The Event Monitor "DB2DETAILDEADLOCK" has reached its file capacity. ) occurs, the DB2DETAILDEADLOCK Event Monitor might need to be redefined with new attributes.

Symptom

Error ADM2017C - The Event Monitor "DB2DETAILDEADLOCK" has reached its file capacity. Delete the files in the target directory directory or move them to another directory.

Cause

Event Monitor has reached its limits settings

Diagnosing The Problem

There is enough space available in the filesystem or directory, but the limits settings for event monitor were reached.

Resolving The Problem


To solve the issue, delete the files in the target directory or move them to another directory.
Or you can run the following steps to redefine the existing definitions:

1) Disable Event Monitor

    db2 set event monitor DB2DETAILDEADLOCK state=0

2) Drop Event Monitor
    db2 drop event monitor DB2DETAILDEADLOCK

3) Recreate Event Monitor (this is an example - change the values properly)
    CREATE EVENT MONITOR DB2DETAILDEADLOCK
       FOR DEADLOCKS
       WRITE TO FILE '<path/filename>'
       MAXFILES <maxfiles_number>
       MAXFILESIZE <maxfilesize>
       AUTOSTART

4) Enable the Event Monitor
    db2 set event monitor DB2DETAILDEADLOCK state=1

Related Information

[{"Product":{"code":"SSEPGG","label":"Db2 for Linux, UNIX and Windows"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"Performance - Event Monitor","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"9.7;9.5;9.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]