S0EC6 ABEND in MODULE BPXPR


Technote (troubleshooting)


Problem(Abstract)

Connect:Direct for z/OS abends with S0EC6 in MODULE BPXPR after upgrading to Z/OS 1.11 or above.

Symptom

DUMP TITLE=COMPON=BPX,COMPID=SCPX1,ISSUER=BPXMIPCE,MODULE=BPXPR
SRB+1582,ABEND=S0EC6,REASON=0BF20050


Cause

The S0EC6 ABEND was introduced as a diagnostic ABEND by USS with APAR

OA35080. No additional z/OS fix is needed.


Environment

Z/OS 1.11 or Z/OS 1.12 or Z/OS 1.13

Resolving the problem

Download POST5000 as of 4-15-2012 or later

and apply fix T050014 -

: PREVENT SEC6 BY USING SEPARATE AIOCB FOR

: CANCEL REQUEST AFTER TIMEOUT. SEC6 APPEARS

: AFTER APAR OA35080 IS APPLIED ON Z/OS V1R11

: AND ABOVE.

LINKLIB UPDATES : DMGSDIPE (2012/03/14)

The fix for 4.8 is T048016 .


The fix for 4.7 is T047086.


Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.