S0EC6 ABEND in MODULE BPXPR

Technote (troubleshooting)


Problem(Abstract)

Connect:Direct for z/OS abends with S0EC6 in MODULE BPXPR after upgrading to Z/OS 1.11 or above.

Symptom

DUMP TITLE=COMPON=BPX,COMPID=SCPX1,ISSUER=BPXMIPCE,MODULE=BPXPR
SRB+1582,ABEND=S0EC6,REASON=0BF20050


Cause

The S0EC6 ABEND was introduced as a diagnostic ABEND by USS with APAR

OA35080. No additional z/OS fix is needed.


Environment

Z/OS 1.11 or Z/OS 1.12 or Z/OS 1.13

Resolving the problem

Download POST5000 as of 4-15-2012 or later

and apply fix T050014 -

: PREVENT SEC6 BY USING SEPARATE AIOCB FOR

: CANCEL REQUEST AFTER TIMEOUT. SEC6 APPEARS

: AFTER APAR OA35080 IS APPLIED ON Z/OS V1R11

: AND ABOVE.

LINKLIB UPDATES : DMGSDIPE (2012/03/14)

The fix for 4.8 is T048016 .


The fix for 4.7 is T047086.