Troubleshooting
Problem
Use the following procedure to collect a trace of the Java classes that are loaded by App Connect Enterprise (ACE) and IBM Integration Bus (IIB) at startup.
Resolving The Problem
To collect a trace of the Java classes that are loaded by ACE/IIB components at startup, complete the following steps:
The classloading trace is written to the Int.Node's/Server's standard output and error files, in the directory $MQSI_WORKPATH$/components/<NODE>.
- Stop your Integration Node.
- Enable tracing by exporting two environment variables:
export IBM_JAVA_OPTIONS=-Dibm.cl.verbose=*
export MQSI_DISABLE_MB_PRINTSTREAM=true - Start your Int.Node from the same shell containing the environment variables.
The classloading trace can be disabled by blanking these variables and restarting your Int.Node, or restarting the Int.Node from a shell without the variables.
The classloading trace is written to the Int.Node's/Server's standard output and error files, in the directory $MQSI_WORKPATH$/components/<NODE>.
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Component":"","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"}],"Version":"11.0","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}},{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Product Synonym
WMB MB WebSphere Message Broker MQ Integrator WBIMB WBI-MB MQSI WMQI
Was this topic helpful?
Document Information
Modified date:
23 March 2020
UID
swg21588070