IBM Support

IRX0406E message in Event Pump

Troubleshooting


Problem

IRX0406E appears in the AOPOUT sysout DD for the Event Pump

Symptom

IRX0406E message in AOPOUT sysout DD for the Event Pump. The message will have the following look:

IRX0406E REXX exec load file AOPEXEC does not contain exec member <module_name>

where module_name is the name of a module that exists in a load library other than that contained in the AOPEXEC DD statement.

Cause

REXX issues this message after failing to find <module_name> in the library or libraries pointed to by the AOPEXEC DD statement however the module exists in a load library contained in the module search path.

Diagnosing The Problem

Review the AOPOUT sysout DD for the Event Pump and search for IRX0406E message.

Resolving The Problem

In cases where <module_name> is contained in a library included in the module search path this message can be ignored and treated as informational in nature as the module will be found and executed successfully. To alleviate the message from appearing in the AOPOUT sysout DD you can add the following parameter to the Event Pump configuration:

EXEC_REFRESH=YES

[{"Product":{"code":"SSXTW7","label":"Tivoli Event Pump for z\/OS"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"--","Platform":[{"code":"PF035","label":"z\/OS"}],"Version":"4.2.0;4.2.1;4.2.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]