Synchronization failure

Technote (troubleshooting)


Problem(Abstract)

ECMDB failure like
DB2 SQL Error: SQLCODE=-204, SQLSTATE=42704, SQLERRMC=DB2INST1.CT_SENSOR_EVENT, DRIVER=3.53.95

Cause

In this sample the table DB2INST1.CT_SENSOR_EVENT doesn't exist on ECMDB

Resolving the problem

./dbquery.sh "select * from CT_SENSOR_EVENT"

If the table does not exist on the ECMDB
1. Run the snapshot.sh command with no parameters on the ECMDB.
2. Run the query above again to make sure it now exists on the ECMDB.
3. If it does exist, restart TADDM on the ECMDB and rerun the sync again