Question & Answer
Question
How do you enable the missing IBM Rational Rhapsody Gateway Option in the project context menu?
Cause
You want to Import your requirements into Rational Rhapsody through Gateway.
Answer
A missing gateway option from the project context menu would mean that rg.ini file currently in use is corrupted.
Following are the steps to enable the Gateway option:
- Edit the file %APPDATA%\rg.ini
- Remove all lines from the sections [Extents] and [Editor] in the INI file:
[Extents]
idConfig=734@542
idMain=1010@732
idOTSEvaluator=719@488
idExport=724@618
idPictureViewer=1286@686
idAddHighLevelRequirements=438@380
idBrowse=458@324
idDoorsWizardWindow=500@443
idDoorsRhapsodySync=780@640
idWordBrowse=250@250
[Editor]
Extent=1026x790
VerticalResizeL=1
VerticalResizeR=0
ImpactModeWithDocument=0
IsStayOnTop=0
InCommon=1
ColWidthValue=3000
HorizontalInterBook=1200
- Restart Gateway
[{"Product":{"code":"SSB2MU","label":"IBM Engineering Systems Design Rhapsody"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"General Information","Platform":[{"code":"PF033","label":"Windows"}],"Version":"7.5.2;7.5.2.1;7.5.3;7.5.3.1;7.5.3.2;7.6;7.6.0.1;7.6.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]