Skip to main content

InfoSphere Datastage: Error using DB2 Bulk Load Stage - Function 'get_stage_prop' failed


Technote (troubleshooting)


Problem(Abstract)

Receiving the following error when using DB2 Bulk Load Stage:

Invalid pointer to stage user data
Internal Error: Function 'get_stage_prop' failed
Error opening file in 'Directory for Data and Command Files'

Resolving the problem

Please perform the following, as applicable:

  • Verify the path in the 'Directory for Data and Command Files' property of the DB2 load stage exists and has write permissions.
  • Ensure the property indicated above is pointing to a path/directory and not a Unix file.

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

InfoSphere DataStage


Software version:
8.0.1, 8.1, 8.5, 8.7


Operating system(s):
AIX, HP-UX, Linux, Solaris, Windows


Reference #:
1570075


Modified date:
2011-12-13

Translate my page