InfoSphere Datastage: Error using DB2 Bulk Load Stage - Function 'get_stage_prop' failed

Technote (troubleshooting)


Problem(Abstract)

Receiving the following error when using DB2 Bulk Load Stage:

Invalid pointer to stage user data
Internal Error: Function 'get_stage_prop' failed
Error opening file in 'Directory for Data and Command Files'

Resolving the problem

Please perform the following, as applicable:

  • Verify the path in the 'Directory for Data and Command Files' property of the DB2 load stage exists and has write permissions.
  • Ensure the property indicated above is pointing to a path/directory and not a Unix file.

Document information

More support for: InfoSphere DataStage

Software version: 8.0.1, 8.1, 8.5, 8.7

Operating system(s): AIX, HP-UX, Linux, Solaris, Windows