IBM Support

Abend S878 Reason Code 10 and U4087 abend

Troubleshooting


Problem

Abend S878 Reason Code 10 and U4087 abend

Symptom

Abend S878 Reason Code 10
All the getmain storage is coming from 24 mode.

Error Message

Abend S878 Reason Code 10

Abend U4087

Resolving The Problem

Solution

1. Increase EXEC REGION in the JCL (Either on the Jobcard or on the individual step)
or
2. Include DD DCB BLKSIZE (or use smaller BLKSIZE). For example: EBDI016 Split Files should have BLKSIZE 8000 (as delivered) or lower, when using more than a few Split Files. When BLKSIZE is Missing or Zero, IBM uses initial BLKSIZE = 32767. The default BUFNO=10 will allocate 327K for each file.
or
3. Include EXEC ,PARM='/ALL(ON)' in the JCL. This allows execution above the line.

[{"Product":{"code":"SS6UG9","label":"Sterling Gentran for z\/OS"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Not Applicable","Platform":[{"code":"PF035","label":"z\/OS"}],"Version":"6.4;6.5;6.6","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]